Installer Manual Fleck 5812 - XTR - Programming
76 / 132
Ref. MKT-IM-019 / E - 14.10.2019
day override/time-driven
: Adjust the day override.
regen. time
: Adjust the regeneration time.
Press
to save and return to the master settings screen or press
to return to the master settings
screen without saving.
6.3.5.3 Softener metered delayed
media volume
: Adjust the volume of resin.
salt dosage
: Adjust the salt dosage.
blfc size
: Adjust the BLFC size
Press
to save and pass to the next screen or press
to return to the master settings screen
without saving.
Valve
regen. time
1 d
02:00 am
day override/
time-driven
Valve
salt dosage
blfc size
30
L
110
g/L
0.500
gpm
media volume
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...