6.3.11. Remote Regeneration screen
From the secondary master settings screen press the
remote regen
button to display the remote
regeneration screen.
remote signal duration
: Contains settings for triggering a regeneration via a remote input. Set a
timing in seconds for contact closure in order to trigger the regeneration.
Connect a remote switch (such as a differential pressure switch) to the remote start input terminals
on the back of the XTR controller board. See 5.8. Electrical connections, page 47. When the remote
switch remains closed for the number of seconds specified in the remote regeneration screen, a
regeneration will be triggered regardless of volume, capacity, or time remaining until the next
scheduled regeneration.
Press
to save and to return to the master settings screen or press
to return to the master
settings screen without saving.
6.3.12. Chlorine generation screen
From the secondary master settings screen press the
cl generation/low salt
button to display the
chlorine generation screen.
Note
Cl generation/low salt will not be available for filter metered, immediate or delayed
regeneration type.
Mandatory
On the valves of series 5810 and 5812, cl generation/low salt must be set
OFF
because the
chlorine cell kit managed by the XTR is not available for those valves.
Remote Regeneration
remote signal
duration
off
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...