Installer Manual Fleck 5812 - XTR - Programming
Ref. MKT-IM-019 / E - 14.10.2019
91 / 132
cl generation/low salt
: Contains settings for the chlorine generation. Select between OFF, low salt
detect. and ON.
regen. interval
: Contains the setting for the chlorine generation interval. Set up from 1 to 255 to
define the interval of regeneration between each chlorination activation, e.g. 1 so that it is enabled at
every regeneration or 10 so that it is activated every 10 regenerations for instance.
Press
to save and to return to the master settings screen or press
to return to the master
settings screen without saving.
6.3.13. Non-factory setting
After all parameters in master setting have been set, press
on the master settings screen to
display the non-factory settings screen.
Press
to save all programmed master settings parameters to non-factory settings. At any point,
the controller can be reset to these saved custom settings (see 6.4.1. Error log, page 94). Press
to
return to the master settings screen without saving.
Chlorine Gen./Low Salt
cl generation/
low salt
0ff
regen. interval
1
Non-factory settings
current settings will
be saved as
the non-factory settings?