Installer Manual Fleck 5812 - XTR - Commissioning
Ref. MKT-IM-019 / E - 14.10.2019
95 / 132
7.
Commissioning
Note
This chapter is available for standard regeneration types. Contact your supplier if the actual
regeneration is not standard and if you need assistance.
7.1.
Water filling, draining and waterproofness inspection
7.1.1. Activating the softener
A
With the bypass still in Bypass position (inlet and outlet of the valve closed), plug in the XTR
controller to the power source.
B
Proceed to programming according to your system specification if not done yet.
C
Start a manual regeneration. The piston will move in backwash position. If first cycle is not BW,
quick cycle the valve until the piston reach BW position. Once in this position, unplug the XTR
controller from the power source.
D
With the outlet manual valve still closed, slowly open the inlet manual valve. The valve and tank
will slowly get filled with raw water, allowing air to be purged by the drain. Open the inlet manual
valve progressively until fully open position.
E
Once the drain runs clear and the inlet manual valve fully open, plug in again the XTR controller
to the power source.
F
Push on the regen button once to move the valve piston to the next regeneration cycle position.
Leave the valve 1 minute in each positions and move to the next one, until refill cycle is reached,
let the valve run the entire cycle and check the level of water in the brine tank. The level of water
in the brine tank should be about 5 cm above the salt platform. You may want to mark the level
on the brine tank as this can be used as an indicator for the future lifetime of the softener.
G
Once refill cycle is completed, quick cycle the valve into service position. Start again a manual
regeneration.
H
Quick cycle the valve to brine draw position. Check to see in the brine tank if the water level
decrease.
I
Once the draw function is observed and confirmed (level of water in the brine tank has
decreased), you may go through each cycle until refill cycle, leave the water come back to the
"full" level, and then quick cycle the valve into service position.
J
Slowly open the outlet manual valve, and close the bypass manual valve. The system is now in
service.
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...