4.
System sizing
4.1. Recommendations
4.1.1. Injector/DLFC/BLFC-Valve configuration
Note
For upflow configuration, it is highly recommended to use the injector cap 61923-20,
equipped with a pressure regulator.
4.1.2. Hard water bypass
Note
This valve allows hard water bypass during regeneration with
DF
,
UF
and filter pistons. A
time based signal (see 6.3.7. Relay output screen, page 84) can be programmed to give a dry
contact signal used to close a shut-off electro valve on the outlet during regeneration.
Valve
type
Tank
diameter
Resin
volume
Injector
DLFC
BLFC
[in]
L
DF
Color
UF
Color
[gpm]
DF [gpm] UF [gpm]
5812/
1650
8
9 - 21
00
Violet
000
Brown
1.5
0.25
0.25
9
22 - 28
0
Red
00
Violet
2.0
10
29 - 42
1
White
0
Red
2.4
12
43 - 56
2
Blue
1
White
3.5
0.50
0.50
13
57 - 70
3
Yellow
2
Blue
4.0
14
71- 85
5.0
16
86 - 113
4
Green
3
Yellow
7.0
21
114 - 198
5
Grey
4
Green
10.0
1.00
1.00
24
199 - 283
15.0
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...