Installer Manual Fleck 5812 - XTR - Programming
Ref. MKT-IM-019 / E - 14.10.2019
67 / 132
water saver regen.
: Set a low water usage regeneration.
remote regen.
: Contains settings for triggering a regeneration via a remote input.
cl generation/low salt
: Contains settings for chlorine generation and salt alarm.
Mandatory
On the valves of series 5810 and 5812, cl generation/low salt must be set
OFF
because the
chlorine cell kit managed by the XTR is not available for those valves.
6.3.2. Master setting reference chart
Note
Some items may not be shown depending on controller configuration.
Note
The controller will discard any changes and exit master settings if any button is not pressed
for five minutes.
Screen name
Parameters
Values
Notes
Format,
Format
Language
English
French
German
Italian
Spanish
Dutch
Portuguese
Changes the language to display screen text
and button labels.
Units
U.S.
Metric
Changes system units and values across all
parameters in the control.
All programmed units and values are
recalculated after adjusting this setting.
Hardness
units
Grain per gallon
mg/L or ppm
German degrees
French degrees
Clark degrees
Changes hardness units used in displaying
hardness parameters and calculating system
capacity and editing exchange capacity and
hardness settings.
Master Settings
remote regen.
cl generation/
low salt
water saver
regen.
Summary of Contents for FLECK 5812 XTR
Page 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Page 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Page 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Page 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Page 132: ...www pentairaquaeurope com...