The working pressure in the hydraulics system must be controlled by a pressure relief valve that is adjusted to 

operate at 10% of the maximum system pressure.

• 

When installing, adjusting or removing a Hypro centrifugal pump, ensure that there are no objects which can fall 

on the installer and make certain that all machinery to which the pump is to be attached is turned off.

• 

Pumps must be installed in a location where they are accessible for any necessary maintenance.

• 

When hydraulic power is used, the system should contain a quick disconnect coupling that can be disconnected 

to isolate the pump.

•         For pumps with gas engines, the exhaust must be directed away from operators and anyone standing nearby to 

ensure that exhaust fumes do not enter their breathing zone.

•         When a main electrical supply is needed to power electric-drive motors, installers are responsible for ensuring 

that a supply disconnect device, capable of isolating the machine from its electricity supply, be provided.

Standard Mounting

•  In order to prevent injury or damage to property, all Hypro pumps should be properly mounted to a solid base where 

there is no danger of the pump falling or breaking loose. All Hypro pumps come with mounting holes which allow bolts 

to be put into the pump so it can be secured to a sturdy base. When mounting your Hypro centrifugal pump, be sure to 

use bolts and nuts which are compatible with any chemicals that may come into contact with them as well as choosing 

the correct grade of bolt based on the pump weight and any expected loads. Pumps should be mounted as close to the 

liquid source as possible. Non self-priming pumps must be mounted below the liquid level to function properly.

Pump Plumbing

•  To achieve maximum pump performance, pump inlet and outlet lines should be at least the same size as their 

respective port, and should have as few restrictions as possible.  Pump plumbing must be capable of withstanding the 

maximum suction and pressure generated by the pump.  Pump suction line must also be free of air leaks.  Use good 

quality suction hose that will not be collapsed by suction.

•  For best priming results, the recommended orientation for the outlet port is pointing straight up.  The upper most vent 

plug can be removed and a vent line can be installed.  This line prevents air lock and allows the pump to prime itself 

by bleeding off trapped air.  Avoid any dips or bends in the suction line plumbing that could trap air.

Hydraulic Installation

•  Prior to installation, refer to the tractor or sprayer manual and determine what type of hydraulic system is being used.  

The three types of systems include:
 

•  Open center systems

 

•  Closed center (Pressure-Compensated) systems

 

•  Closed center Load Sensing (Flow and Pressure-Compensated) systems

•  The hydraulic motor must be correctly configured and sized for the hydraulic system:
 

•  Open center systems

 

 

•  Excess oil from the hydraulic pump must be bypassed around the motor

 

 

 

•  Built in bypass option in motor endplate, or separate bypass valve installed in the line feeding    

 

 

 

    the motor inlet.

 

 

•  Use the largest motor possible

 

•  Closed center (Pressure-Compensated) systems

 

 

•  Metering orifices needed for optimal performance (see metering orifice section below).

 

 

•  Use the smallest motor possible

Ref. 

No. Description

1

Tank Lid

2

Vent Line

3

Jet Agitator

4

Shut-off Ball Valves

5

Centrifugal Pump

6

Spray Control Console

7

Centrifugal Pump Control

8

Manifold Boom Valve

9

Flowmeter

10

Jet Turret Nozzle Body

Summary of Contents for HYPRO 9302C Series

Page 1: ...SERIES CENTRIFUGALPUMPS 9302C 9302S L 1593 Rev B 12 09 19 Pentair 375 5th Ave NW New Brighton MN 55112 Phone 651 766 6300 OR 800 424 9776 Fax 800 323 6496 www pentair com EC REP EU Authorized Represe...

Page 2: ...sport and Intermediate Storage 8 Assembly and Installation 9 Assembly 9 Installation 9 Plumbing Diagram 10 Control Systems 11 Commissioning Start Up Operation Shut Down 11 Information 11 Start up Oper...

Page 3: ...ingua andare a www hypro pentair com Italian Hypro www hypro pentair com Russian NO intente instalar su bomba antes de leer el manual Copias originales del manual para Hypro se provee de bombas en ing...

Page 4: ...ion or maintenance information that is important but not safety related This symbol is used to denote the presence of an electrical hazard that will result in personal injury death or property damage...

Page 5: ...al Data All specifications and performance data are based on water as a carrier fluid 9302C HM1C HM2C HM4C 9302S HM1C HM2C HM4C 9302CT GM1 9302ST GM1 E C B D A H I G F Pump Dimensions Dim Inch Mm HM 1...

Page 6: ...n 25 11 3 2 X 3 8 or M10 9302C HM1C 100 6 9 13 49 2 72 272 5 150 10 3 1 2 NPT Inlet 3 4 NPT Outlet 4 SAE Case Drain If equipped 27 12 3 9302C HM2C 2600 179 6 22 7 65 246 1 96 6 6 26 11 8 9302C HM4C 8...

Page 7: ...7 Form L 1593 Rev B 12 09 19 7...

Page 8: ...e present and undamaged If the pump is missing components contact customer service immediately Once the pump is unpacked dispose of the packaging in a manner compliant with local and national regulati...

Page 9: ...void your warranty and could cause damage to property serious personal injury or death Electrical power cables and pump hoses must be routed where there is no risk of personnel tripping walking into...

Page 10: ...possible Non self priming pumps must be mounted below the liquid level to function properly Pump Plumbing To achieve maximum pump performance pump inlet and outlet lines should be at least the same si...

Page 11: ...used if the hydraulic system is a load sensing flow compensated closed center system or if it is an open center system with a maximum flow of 8 gpm 30 28 lpm for HM2C or 10 gpm 37 85 lpm for HM4C Cor...

Page 12: ...ld lead to property damage serious injury or death Start up Operation Shutdown Before Starting the Pump Ensure all unnecessary personnel are clear of the area For initial setup and test of your system...

Page 13: ...and pump RPM could cause damage to the pump s drive system Closed Center Pressure Compensated HM2C and HM4C Models Only Adjusting Centrifugal Pump Output 1 Open the bypass adjusting screw in the hydr...

Page 14: ...raulic motor Hydraulic system overheating Hydraulic bypass needs adjustment See Installation Insufficient hydraulic hose size See Installation Cleaning Your pump will last longer and give best perform...

Page 15: ...1 3430 0332 Gasket 7 1 3430 0332 Mechanical Seal Viton Ceramic Std 9302C 7 1 3430 0589 Mechanical Seal Viton Silicon Carbide Std 9302S 8 1 0750 9300C Mounting Flange 9302C 8 1 0756 9300S Mounting Fla...

Page 16: ...02ST 9 1 3430 0332 Mechanical Seal Viton Ceramic Std 9302CT 9 1 3430 0589 Mechanical Seal Viton Silicon Carbide Std 9302ST 10 1 1610 0012 Key 9302CT 10 1 04432 SHW Key 9302ST 11 1 3430 0332 O ring 12...

Page 17: ...17 Form L 1593 Rev B 12 09 19 17 Notes...

Page 18: ...18 Form L 1593 Rev B 12 09 19 18 Notes...

Page 19: ...d during installation by a third party Description PENTAIR Pump Type Roller Pumps Series Numbers 1502 1700 4001 4101 6500 7560 7700 Type Centrifugal Pumps Series Numbers 1442P 1539 1540 1542P 1543P 15...

Page 20: ...l or consequential damages of any kind incurred by the reason of the use or sale of any defective product RETURN PROCEDURES All products must be flushed of any chemical ref OSHA section 1910 1200 d e...

Reviews: