7. CLEANING & MAINTENANCE
7.1 Cleaning Cleanload Nexus
IMPORTANT
: The following procedure must be followed after filling
the sprayer to ensure that the internal parts of the Cleanload Nexus
and the Suction Hose are kept clean and free of chemical residues.
!
WARNING
When cleaning Cleanload Nexus, always wear the
recommended personal protective equipment.
NOTE
: Cleanload Nexus is not automatically cleaned when using
any of the sprayers cleaning programs.
Pay special attention to cleaning when changing crops and/or
chemical product.
Be careful when disconnecting Cleanload Nexus and hoses
from the sprayer. Residues might be left in the hoses and on
connections.
Before cleaning, ensure the clean water supply is connected and
that the suction is on and drawing from the Cleanload Nexus.
Fill a 10-litre container with clean water or a suitable cleaning liquid
and securely fit a clean easyconnect cap (one cap is supplied for
this purpose).
Secure the container onto the Cleanload Nexus as described in
Section 6.2 of this manual.
Fully discharge the contents from the container and follow the
rinsing procedure described in Section 6.4.
NOTE
: Ensure that this final rinse procedure is carried out with
CLEAN water. Failure to do this could result in contamination
remaining in the Cleanload Nexus and hoses and damage to the
Cleanload Nexus.
7.2 Storing Cleanload Nexus
‘It is recommended that Cleanload Nexus is disconnected and
removed from the sprayer or mounting location when it will not be
used for some time and placed in storage.
Prior to removal:
Ensure that the Cleanload Nexus has been cleaned according to
the instructions in Section 7.1.
Disconnect the Suction Hose (Ref.4) and Rinse Supply Hose (Ref. 7
& 10). The ear clamps (8) that secure the Rinse Water Hoses can be
removed using a bolt cutter.
NOTE
: New ear clamps (22-25mm) will be required to reconnect
the rinse hoses.
To winterize, discharge a container of anti-freeze through the
Cleanload Nexus. Collect excess anti-freeze as it flows from the
Hosetail Outlet (Ref. 6) and store / dispose of in accordance with
guidelines.
When storing Cleanload Nexus:
∙
Ensure that it is secure and inaccessible to children and animals.
∙
It is always stored in frost free conditions.
CLEANLOAD NEXUS
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
20