IntelliTouch i-Link Protocol Interface Adapter User’s Guide
SPILLWAY
WFALL:
Waterfall/Spillway Control
Control/Query/Toggle Pump (pool).
Request State:
Query:
#WFALL ?<cr>
Response:
!00 WFALL = x<cr>
(RSPFMT = 0)
!00 x<cr>
(RSPFMT = 1)
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Set State:
Command:
#WFALL = x<cr>
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Response:
!00 WFALL = x<cr>
(RSPFMT = 0)
!00 x<cr>
(RSPFMT = 1)
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Toggle State:
Toggle:
#WFALL <cr>
Response:
!00 WFALL = x<cr>
(RSPFMT = 0)
!00 x<cr>
(RSPFMT = 1)
Where x is 1 or 0, and 1 indicates ON, 0 indicates OFF
Note:
The WFALL commands assume a circuit has been configured as a
Waterfall. If there are circuits configured, the response will be an error
message.
?23 OPTION SWITCH NOT SET
Note:
The keyword WFALL and SPILLWAY are interchangeable.
10