IntelliTouch i-Link Protocol Interface Adapter User’s Guide
Connecting to the Indoor Control Panel
To connect the i-Link communication cable to the Indoor Control Panel:
1.
Switch the main power OFF to the Load/Power Center.
2.
Route the four conductor cable from the IntelliTouch i-Link adapter to
the location of the Indoor Control Panel.
3.
Remove the control panel front cover
: From the front of the control
panel, insert the tip of a small flat-blade screwdriver into the notch on
the top edge of the control panel cover and gently pry the cover off from
the control panel base.
4.
Remove the two control panel base retaining screws.
5.
Carefully lift the control panel base up from the wall-mounted sheave
and remove the base from the wall.
6.
Turn the base over and disconnect the four screw terminal plug from the
circuit board.
7.
Strip back the four cable conductors ¼ in. Insert the four wires into the
each of the screw terminals with the existing wires. Secure the wires
with the four screws. Make sure to match the color-coding of the wires:
Red = +15 VDC, Yellow = +DT, Green = -DT, and
GND = Black. Wiring details are shown above.
8.
Insert the screw terminal connector onto the pins on the circuit board.
Note that the connector is keyed for the correct orientation.
9.
Place the control panel base onto the wall-mounted sheave and secure
in place with the two retaining screws.
10. Carefully snap-on the control panel front cover to the base plate.
11. Switch on the power source to the Power/Load Center.
1 GND
BLACK
2
-D
GREEN
3
+D
YELLOW
4
15V
RED
Indoor Control Panel (rear view)
23