IntelliTouch i-Link Protocol Interface Adapter User’s Guide

Start-up Sequence

Each time the IntelliTouch i-Link adapter is powered up a start-up initialization
sequence is sent to the Home Automation system via the RS-232 port and the
current command characters display. These special command characters are also
user definable and may differ from the default characters show below. The
default command character set displays after a start-up sequence. To display these
characters power down/up or reset the IntelliTouch i-Link adapter. For the RST (reset)
command information, see page 4.

IntelliTouch i-Link Adapter Default Command Characters
Pentair Water Pool and Spa - IntelliTouch i-Link Protocol InterfaceAdapter v1.0

CMDCHR = #

NRMCHR = !

ERRCHR = ?

SETCHR = =

INQCHR = ?

Acquiring System Data

!READY

The IntelliTouch system implements an addressing method upon power
up. For most systems the initialization is automatic. The IntelliTouch i-Link
adapter will automatically lock on to the address within two minutes after
power is applied.

Note: 

If there is an IntelliTouch MobileTouch

®

 wireless control panel installed,

the MobileTouch Transceiver

screw terminal connector needs to be removed

from the Transceiver circuit board before the IntelliTouch i-Link adapter
initialization sequence. Refer to Start-up with MobileTouch Control Panel, see
page 25 for details.

IntelliTouch i-Link Adapter

Software Commands

Overview

This manual provides IntelliTouch

®

 i-Link

 software control commands for

IntelliTouch system equipment such as lights, pumps etc. For additional
information about the IntelliTouch control system, refer to the IntelliTouch User’s
Guide (P/N 520102).

1

Summary of Contents for i-Link

Page 1: ...IntelliTouch i Link Protocol Interface Adapter User s Guide IntelliTouch i Link Protocol Interface Adapter User s Guide pool spa control system ...

Page 2: ...es Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the propri etors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others P N 520450 Rev B 10 09 09 Download PDF manuals IntelliTouch User s Guide P N 520102 a...

Page 3: ...leaner Control 9 SPILLWAY WFALL Waterfall Spillway Control 10 Control Heat Source Heat Method 12 Special COMMAND Only commands 14 IntelliBrite LED Lights and MagicStream Lamiinars 14 Sam Sal PG2000 Fiber Optic Lights 14 ALLLIGHTS All Lights Control 15 COLORSWIM Colored Lights Control 15 Special QUERY only commands 15 POOLTMP Current Temperature 15 OPMODE Current System Mode 16 UNITS Current Temper...

Page 4: ...CMDCHR NRMCHR ERRCHR SETCHR INQCHR Acquiring System Data READY The IntelliTouch system implements an addressing method upon power up For most systems the initialization is automatic The IntelliTouch i Link adapter will automatically lock on to the address within two minutes after power is applied Note If there is an IntelliTouch MobileTouch wireless control panel installed the MobileTouch Transcei...

Page 5: ...e Operator is i e set this circuit to value Where the Value is 1 i e ON The Prefix and the Operator must be the correct symbols The Label must be exact spelling from the command list Though it may be Upper or lower case or any combination The Value must be one of the valid options and valid for that command ON values are 1 ON Y or YES T or TRUE OFF values are 0 OFF N or NO F or FALSE A single spac...

Page 6: ...used between the Label and Operator and the Operator and cr No space s is allowed between the Prefix and the Label Error Messages Responses Form Prefix Error Number Message cr RSPFMT 0 Prefix Error Number cr RSPFMT 1 Example 02 BAD COMMAND FORM Where the Prefix is factory default may be changed with ERRCHR Where the Error Number 02 Where the Message is BAD COMMAND FORM If RSPFMT is terse RSPFMT 1 ...

Page 7: ... Query Command Response Format Query RSPFMT cr Response 00 RSPFMT x cr Where x is 1 or 0 0 indicates a verbose response as shown If the RSPFMT is set to terse the response would appear as 00 x cr Command RSPFMT x cr Response 00 RSPFMT x cr Where x is 1 or 0 0 indicates a verbose response as shown If the RSPFMT is set to terse the response would appear as 00 x cr COSMSGS Set Query Change Of System ...

Page 8: ...r Value Query ERRCHR cr Response 00 ERRCHR x cr Where x is the character used to prefix all Invalid responses or error messages from adapter By default this Command ERRCHR x cr Response 00 ERRCHR x cr Where x is the character you wish to make the ERRCHR On Power up or Reset the current value is displayed SETCHR Set Query Set Character Value Query SETCHR cr Response 00 SETCHR x cr Where x is the ch...

Page 9: ...SPA x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle SPA cr Response 00 SPA x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF PUMP Pool Control Control Query Toggle Pump pool Request State Query PUMP cr Response 00 PUMP x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Set Sta...

Page 10: ...ten 10 auxiliary circuits in the second power center AUX21 through AUX30 Control up to ten 10 auxiliary circuits in the third power center AUX31 through AUX40 Control up to ten 10 auxiliary circuits in the third power center AUX41 through AUX50 Control up to ten 10 feature or macro that exist in most systems Note The adapter will not verify the existence of a given circuit For example if a command...

Page 11: ...e x is 1 or 0 and 1 indicates ON 0 indicates OFF If the Dimmer is ON the xx will follow indicating the level 30 40 50 60 70 80 90 and 100 are all valid 00 xxx cr RSPFMT 1 Where xxx is 0 to indicates OFF and is a value to indicate level If ON The Value is 128 i e 30 128 30 158 Inc Dec Level Increment AUXxx cr increase dimmer level if at 100 go to 30 Decrement AUXxx cr decrease dimmer level if at 30...

Page 12: ... x cr Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 00 CLEANR x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle CLEANR cr Response 00 CLEANR x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Note The CLEANR commands assume a circuit has been configured as a cleaner If there are no circuits confi...

Page 13: ...1 or 0 and 1 indicates ON 0 indicates OFF Response 00 WFALL x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle WFALL cr Response 00 WFALL x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Note The WFALL commands assume a circuit has been configured as a Waterfall If there are circuits configured the response wil...

Page 14: ...POOLSP xx cr Where xx is the desired temperature Response 00 POOLSP xx cr RSPFMT 0 00 xx cr RSPFMT 1 Where xx is the current temperature value in ASCII of the Pools desired heating set point Note POOLSP2 is valid only on Models i9 3S and i5S It is used to set the High Temperature It is equivalent To SPASP POOLSP Inc Dec temperature Set Point POOLSP POOLSP is used for the example SPASP SPASP Inc De...

Page 15: ...1 or 0 and 1 indicates ON 0 indicates OFF Set State Command POOLHT x cr Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Response 00 POOLHT x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Toggle State Toggle POOLHT cr Response 00 POOLHT x cr RSPFMT 0 00 x cr RSPFMT 1 Where x is 1 or 0 and 1 indicates ON 0 indicates OFF Note Turning POOLHT ON will enable the ...

Page 16: ...at 00 POOLHT 1 Pool Heating Selection has changed to ON Heater 00 SOLHT 1 Pool Heating Selection has changed to Solar Only 00 SOLPREF 1 Pool Heating Selection has changed to Solar Preferred Spa Heating 00 SPAHT 0 Spa Heating Selection has changed to OFF No Heat 00 SPAHT 1 Spa Heating Selection has changed to ON Heater 00 SPASOLHT 1Spa Heating Selection has changed to Solar Only 00 SPASOLPREF 1SpaH...

Page 17: ...IM Start a Color Swim Sequence COLORSET Set Lights to pre selected Colors COLORSYNC Synchronize All Color Lights The following commands only support the IntelliBrite LED lights IB_PARTY Set ALL IntelliBrite Units to PARTY mode IB_ROMANCE Set ALL IntelliBrite Units to ROMANCE mode IB_CARIBBEAN Set ALL IntelliBrite Units to CARIBBEAN mode IB_AMERICAN Set ALL IntelliBrite Units to AMERICAN mode IB_SU...

Page 18: ... Send Command Command COLORSET cr Response 00 COLORSET 1 cr RSPFMT 0 00 1 cr RSPFMT 1 Note The Color Commands only operate the lights configured in the special Lights screen of IntelliTouch Indoor Control Panel COLORSWIM Start a Color Swim Sequence COLORSET Set Lights to pre selected Colors COLORSYNC Synchronize all Color Lights Special QUERY only commands POOLTMP Current Temperature SPATMP Query ...

Page 19: ...iTouch Model Type Query Model Type Request State Query MODEL cr Response 00 xxx cr RSPFMT 0 00 xxx cr RSPFMT 1 Where xxx is i9 3 i7 3 i5 i9 3S i5S i10 3D For more details about IntelliTouch model refer to IntelliTouch User s Guide P N 520102 16 PUMPLO PUMPHI Pump Status Two Speed Pumps Only Option must be set Query Pump Request State Query PUMPLO cr Response 00 PUMPLO x cr RSPFMT 0 00 x cr RSPFMT ...

Page 20: ...ick Properties 7 Click the Settings tab 8 Click ASCII Setup 9 Click to place a check mark in Send Line Ends with Line Feeds Echo Typed Characters Locally Append Line Feeds to Incoming Line Ends 10 Click OK Click OK again 11 Now in the Hyper Terminal window type RST enter It will take approx 10 seconds for the iLink to complete a reset process The screen will then display some start up text similar...

Page 21: ...ripping cable wires Summary Information For connection options refer to the IntelliTouch i Link Adapter Connection Diagram page 19 The recommended connection steps for the IntelliTouch i Link adapter are Switch power off to the IntelliTouch Load Power Center Before connecting cables to the IntelliTouch i Link adapter switch off the power source to the Load Power Center Connecting to the Home Autom...

Page 22: ... communication port on the IntelliTouch Personality Board Load Center or Power Center via a Serial cable four wire This connection provides power to the IntelliTouch i Link adapter For wiring and connection details see the Connection Diagram below The IntelliTouch i Link adapter operates at 9 6 kbps 9600 kilobits per second using 8 data bits 1 start bit 1 stop bit and no parity IntelliTouch i Link...

Page 23: ...tion details see page 19 IntelliTouch i Link RS 232 DB 9S Signal Description The IntelliTouch i Link adapter RS 232 DB 9S connector pin outs and signal names Note Pins 1 4 and 6 connected Pins 7 and 8 connected S 9 B D r e b m u N n i P E C D e m a N l a n g i S n o i t c e r i D l a n g i S 1 t c e t e D r e i r r a C a t a D D C D t u p n I 2 a t a D e v i e c e R D X R t u p t u O 3 a t a D t i...

Page 24: ...sert the blade into one of the side notches and pry apart the case not completely Remove the screwdriver blade from the notch and insert the blade into the other notch and pry apart to separate the two halves of the adapter case 3 Remove the screw terminal connector from the circuit board Please observe Electrostatic Sensitive Device ESD handling precautions when removing the connector 4 Strip bac...

Page 25: ...ch i Link Protocol Interface Adapter User s Guide Screw Terminal Connector Connect to Indoor Control Panel or Personality Board Notch Wire Exit Hole 4 V 5 1 D E R 3 T D L E Y 2 T D N R G 1 D N G K L B Figure 1 22 ...

Page 26: ...the wall mounted sheave and remove the base from the wall 6 Turn the base over and disconnect the four screw terminal plug from the circuit board 7 Strip back the four cable conductors in Insert the four wires into the each of the screw terminals with the existing wires Secure the wires with the four screws Make sure to match the color coding of the wires Red 15 VDC Yellow DT Green DT and GND Blac...

Page 27: ...onality board that connects directly to the IntelliTouch i Link adapter To connect the cable to the Personality board 1 Switch the main power OFF to the Load Power Center 2 Unlatch the front door spring latche s and open the front door of the Power Load Center 3 Remove the screws securing the high voltage cover panel Remove the cover panel from the enclosure 4 Loosen the two upper access screws fr...

Page 28: ... more information 6 Switch the main power off to the Load Power Center 7 Reconnect the transceiver screw terminal connector onto the transceiver board 8 Slide the case on to the transceiver back plate Secure the transceiver case with the two retaining screws 9 Switch the main power on to the Load Power Center The i Link adapter start up procedure is complete 7 Strip back the cable conductors in In...

Page 29: ...IntelliTouch i Link Protocol Interface Adapter User s Guide BLK GRN YEL RED Power Center Left side of Personality Board 26 ...

Page 30: ...Remove the two retaining screws from the transceiver case Slide the case up to remove 3 Remove the transceiver screw terminal connector from the transceiver circuit board 4 Switch the main power on to the Load Power Center 5 The i Link adapter will power up and initialize the start up procedure and assign an address to the installed equipment This process may take up to two minutes To initialize t...

Page 31: ...Personality Kit installation Used for distributing power for controlling IntelliTouch Systems Also known as the sub panel Low Voltage Compartment Top compartment of Load Center for all low voltage wiring Low Voltage Raceway Vertical space in the left side of Power Load Center for low voltage cabling MagicStream Laminar Water effect designed to provide a clear turbulence free stream of water that c...

Page 32: ...IntelliTouch i Link Protocol Interface Adapter User s Guide 520450 P N 520450 Rev B ...