IntelliTouch i-Link Protocol Interface Adapter User’s Guide
Query Command Forms
[Prefix][Label][Operator]<cr>
Example: #SPA?<cr> (Query SPA State)
Where the Prefix is “#” (factory default – may be changed with CMDCHR)
Where the Label or Command is “SPA”
Where the Operator is “?” i.e. Query
The Prefix and the Operator must be the correct symbols. The Label must be exact
spelling from the command list using upper or lower case, or any combination. A
single space may or may not be used between the Label and Operator, and the
Operator and <cr>.
No space(s) is allowed between the Prefix and the Label.
Error Messages/Responses Form
[Prefix][Error Number][Message]<cr>
(RSPFMT = 0)
[Prefix][Error Number]<cr>
(RSPFMT = 1)
Example: ?02 BAD COMMAND FORM
Where the Prefix is “?” (factory default – may be changed with ERRCHR)
Where the Error Number “02”
Where the Message is “BAD COMMAND FORM”
If RSPFMT is terse (RSPFMT = 1) only the Prefix and Error Number are
returned
Error Messages:
“01 INVALID COMMAND”
“02 BAD COMMAND FORM”
“11 485 SET/GET VALUE TIME-OUT”
“22 AUX OFF: DIMMER CTL IGNORED”
“23 OPTION SWITCH NOT SET”
“88 INTERFACE BUSY”
“98 UNKNOWN ERROR CONDITION”
“99 UNKNOWN COMMAND VALUE”
3