9
IntelliFlo VS+ SVRS Installation and User’s Guide
IntelliFlo VS+ SVRS Menus
Press MENU button to access menus
MAIN SCREEN
(page 10)
SETTINGS
(1-16) Default: ADDRESS 1
(hr:mm) Default: 12:00 AM
Set AM/PM
AM/PM
24 hr.
Fahrenheit - Default: F˚
C˚ Celsius
(1-5) Default 3
(1100 RPM - 1700 RPM) - Default: 1100 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Pump Address
Set Time
Temperature Unit
Screen Contrast
Language
Set Min Speed
Set Max Speed
PASSWORD
Password Time Out (1 min. - 6 hours) Default:10 minutes
Disabled/Enabled - Default: Disabled
Enter Password (xxxx) Default: 1234
(page 12)
SPEED 1-8
Speed 1 (1-4)
Manual
Schedule
Egg Timer
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
(page 17)
EXT CONTROL
Program 1
Speed - Default: 1100 RPM
Speed - Default: 1500 RPM
Program 2
(page 17)
FEATURES
Quick Clean
Set Speed (1100 -3450 RPM) Default: 3450 RPM
Time (1 min. to 10 hrs.) Default: 10 minutes
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Time Out
(page 19)
PRIMING
DISABLED/ENABLED
(1 min. to 30 min. hrs.) Default: 11 minutes
MAX PRIMING TIME
(page 21)
ANTI FREEZE
Disabled / Enabled - Default: Enabled
Program 3
Speed - Default: 2350 RPM
Speed - Default: 3110 RPM
Program 4
English - Default: English
SVRS Auto Restart
SVRS Restart Time (30 sec. - 5 mins.) Default 2 minutes
Disabled/Enabled - Default: Enabled
Speed 5 (5-8)
Schedule
Set Speed
Set Start Time
Set Stop Time
RAMP SPEED
(5 RPM - 400 RPM) Defualt: 200 RPM
Disabled
Default: Disabled
Default: Enabled
(1 - 100%) Default: 1
PRIMED SENSITIVITY
(1 second - 10 minutes) Default: 20 seconds
PRIMING DELAY
DISABLED/ENABLED
SET SPEED
40˚ F - 50˚ F (4.4˚ C - 10˚ C) Default: 40˚ F (4.4˚ C)
PUMP TEMPERATURE
Set Speed (1100 RPM - 3450 RPM) Default 1100 RPM