9
INTELLIFLO
®
Variable Speed Pump Demo Kiosk Operation and Set Up Instructions
INTELLIFLO
®
Variable Speed Pump Demo Kiosk Operation and Set Up Instructions
Pressure Tube Set
(Included with Optional Pressure
Sensor Unit)
1. Install the red and blue color coded tube ends into the
corresponding marked connections (orange flanged
adapters) on the pressure sensor box.
2. Route the pressure tube quick disconnect ends
through the opening in the cabinet divider wall and up
through the pump board.
3. Push the quick release metal tabs on the connectors
at the pump to install the tube ends.
RED end goes to the HIGH pressure connector
(discharge).
BLUE goes to the LOW pressure connector (suction).
Finished Demo Unit
Note: When connecting sensor tubing to Pressure Sensor
Box Unit, insert tubing into orange flanged adapter, then
push firmly another ¼” until tube “bottoms out” in the socket
to prevent leakage.
Note: To disconnect – slide orange shoulder flange back
while pulling on tube.
IMPORTANT!
1
3
Pressure Sensor
Tubes
High Pressure
(Discharge)
Low Pressure
(Suction)