120V/240V A/C Step-Up Transformer
The cabinet is a completely self-contained unit, with the
exception of the power cord connected externally to an
AC power source.
Set the input voltage for the transformer to the proper
voltage for your country or region.
1. Verify that the
transformer power switch is set to
the OFF position.
2. Set the Voltage Input Selector “TAP PLUG” to the
proper voltage used in your country, or region.
Transformers are shipped set to the 110V position.
(see image, top right).
3. Put the AC power cable found on the back of the
transformer through the hole located in the back
of the cabinet. Attach the cable to a wall AC outlet
having a minimum rating of 20 Amps.
4. Plug the AC terminal strip into the transformer outlet
labeled ‘Terminal Strip Power’. (Note: AC power cord
for unit vent fan and computer are already connected
to AC terminal strip).
5. Plug the heavy black 12-guage power cord Into
the transformer outlet labeled ‘Pump Power’. Plug
the other end of the black 12 guage cable into the
DAQ-202 “Black Box” socket labeled ‘Line In Power’
(see image below).
Voltage Input
Selector set at
110V
Transformer
“Black Box”
Plug AC power
strip into outlet
labeld ‘Terminal
Strip Power’ on
transformer
TERMINAL
STRIP
POWER
TERMINAL
STRIP
POWER
PUMP
POWER
PUMP
POWER
PUMP
POWER
LINE IN
POWER