Page 1: ...B 44665 21 1403 www jung pumpen de EN Instruction Manual JUNG PUMPEN OXYPERL ...

Page 2: ...n ergy must be prevented Leakages of dangerous e g explosive toxic hot substances must be discharged such that no danger to people or the environment occurs Legal regulations must be observed Safety instructions for instal lation inspection and main tenance works As a basic principle works may only be car ried out to the equipment when it is shut down Pumps or plant that convey harmful substances ...

Page 3: ...CTION Only qualified electricians may carry out electrical works to the pump or the controls The relevant standards such as EN stand ards country specific regulations such as VDE in Germany and the regulations of the local power supply companies must be ob served ATTENTION Never put the free lead end in water If water gets into the plug this can cause malfunctions and damage Observe the operating ...

Page 4: ... and the propeller must not be greater than 1 mm as otherwise the mechanical seal on the OXYPERL will not be sufficiently pre stressed and oil leaks may occur Tightening torque MA of the screws M 6 with MA 5 Nm Amtec 3 5 with MA 1 Nm and Amtec 5 0 with MA 2 Nm Air reflux valve Accessory A particularly for problematic cases de veloped optional air reflux valve presents a pressure compensation when ...

Page 5: ...______________ ppa ____________________ Stefan Sirges General Manager Frank Erdt Sales Director DE Weitere normative Dokumente CZ Jinými normativními dokumenty DK Andre normative doku menter EN Other normative documents FI Muiden normien FR Autres documents normatifs HU Egyéb szabályozó dokumentumokban leírtaknak IT Altri documenti normativi NL Verdere normatieve documenten PL Innymi dokumentami n...

Page 6: ...p cover JP46928 Kabelbaum Cable gland Oxyperl 3 JP46921 Oxyperl 5 JP46930 Leitung Cable 1 5 m JP46925 4 m JP46926 10 m JP45084 20 m JP46927 Belüftergehäuse Aerator housing Oxyperl 3 JP45082 Oxyperl 5 JP46196 Motoreinheit Motor unit Oxyperl 3 JP45081 Oxyperl 5 JP46195 Propeller Propeller Oxyperl 3 JP45083 Oxyperl 5 JP46197 Ausgleichscheiben Compensating disks JP45109 Schraubensatz Screw set JP42773...

Page 7: ...7 ...

Page 8: ...Pump Technical Services Limited Pump House Unit 12 Bilton Road Industrial Estate Erith Kent DA8 2AN Tel 01322 357 080 Fax 01322 341 341 Email sales pts jung co uk ...