56
SECTION 8: Pentek Intellidrive
™
Variable Frequency Drives
3. Pump out well (if necessary):
Direct pump’s discharge to appropriate location
not connected to system and press Pump Out.
Drive will ask “Is a valve open?” Change “No”
to “Yes”, press enter. The pump will run at 45 Hz.
Adjust frequency as appropriate:
A. Press ENTER
B. Change frequency value
NOTICE Above ground pumps should run at 60
Hz for this step (until pump is primed). Then
adjust frequency as necessary.
C. Press ENTER again.
Run the Drive in this mode until the well
discharge runs clear, then press STOP button to
stop Drive.
Risk of explosion. In Pump Out
mode, pump runs at a constant speed. All
pressure functions are not working, there is no
sleep or Dry Run Protection which can cause very
high pressure if flow is restricted.
4. Verify installation: Make sure that the system
has properly-sized, pressure-relief valve and
pressure tank.
Make sure pressure tank’s precharge is correct.
See Table 7.
Make sure pump discharge is connected to
system.
5. System Start:
A. Open valves at the ends of lines so that air
will escape during pressurization.
B. Press Auto Start; close valves at the ends of
lines after all air has escaped.
C. The system goes into Constant Pressure
Operation as soon as the transducer
registers the Dry Run Sensitivity parameter
(default is 10 PSI). If system pressure does
not reach that PSI value within 3 minutes,
the Drive will stop. Press Auto Start again to
restart line fill. If longer priming or line fill
time is required, adjust Fill Time parameter.
See Table 9.
Changing a Parameter Value
This procedure works for ANY parameter.
A. Press MAIN MENU button.
B. Follow the keypress sequence shown in
Figure 12:
A shorthand way to remember this is:
• Press ENTER to change a value
• Press ENTER again to save it
• If new value is not saved, any screen change will
result in the loss of the new value.
Table 9 lists all available commands and
parameters for the Pentek Intellidrive.
6567 0512
Use arrows to
find parameter
Use arrows
to change value
Press Enter
to save
Press Enter
Figure 12 - Changing parameter value.
Table 8 - Pentek Motor Service Factor Amps
Motor
Type
PENTEK
®
Part
Number
Rating @
230V
Service
Factor
Amps
HP
2-Wire
P42B0005A2-01
1/2
4.7
P42B0007A2-01
3/4
6.2
P42B0010A2-01
1
8.1
P42B0015A2-01
1-1/2
10.4
P42B0005A2
1/2
4.7
P42B0007A2
3/4
6.4
P42B0010A2
1
9.1
P42B0015A2
1-1/2
11.0
CS/CR
3-Wire
P43B0005A2-01
1/2
4.8
P43B0007A2-01
3/4
6.0
P43B0010A2-01
1
7.3
P43B0015A2-01
1-1/2
10.9
P43B0005A2
1/2
4.9
P43B0007A2
3/4
6.3
P43B0010A2
1
7.2
P43B0015A2
1-1/2
11.1
P43B0020A2
2
12.2
3-Phase
P43B0005A3
1/2
2.9
P43B0007A3
3/4
3.9
P43B0010A3
1
4.7
P43B0015A3
1-1/2
6.1
P43B0020A3
2
7.6
P43B0030A3
3
10.1
P43B0050A3
5
17.5