Page 1: ..._________ OWNER S MANUAL Should you the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor manufacturer for the co...

Page 2: ..._________ 1 Precautions and General Notes 3 2 Parts Included 4 3 Product Information 5 3 1 Product Features 5 3 2 Specifications 5 3 3 Schematic Diagrams 6 3 4 Introduction to Main Parts 8 4 Installat...

Page 3: ...the bypass It is not recommended to use sealants on the threads Use Teflon tape on all threaded connections Teflon is a trademark of E I duPont de Nemours General Observe all warnings that appear in...

Page 4: ...________________________________________ Open the package and ensure that all parts are provided All models of carbon filter contain the following parts 1 Carbon filter with automatic control valves 2...

Page 5: ...ters use Chlorinated city water as the inlet water they are suitable for filtration treatment of potable water in places with high daily water demand such as homes hotels guesthouses and restaurants 3...

Page 6: ..._______________________________________________ 3 3 Schematic Diagrams Electrical Control Diagram Drain Inlet Outlet Media Tank Riser Tube Activated Carbon Gravel Optical Sensor 220VAC 12VAC Socket 1...

Page 7: ..._________________________________________________________________ VALVE LAYOUT 363TC Flow Diagrams SERVICE BACKWASH Recycle Button Time Button Remove Cover Backwash Duration Button Cleaning Cycle Inte...

Page 8: ...l 3 5 mm 8kg KDF Copper zinc alloy Diameter 0 149 2mm PCFE40P12 500g PCFE54P12 600g Polyethylene PE Media Tank Lining Polyethylene Diameter 250mm 1 piece Housing Fiberglass Height PCFE40P12 Model 1020...

Page 9: ...ter the water filtration system Generally influent turbidity should be controlled at less than 5NTU Generally the carbon filter is installed after the water meter at the entrance of indoor tap water t...

Page 10: ...r the better to perform a backwash for several hours This is to ensure optimal performance of the filtration system when restarted In the event of occasional water stoppage or power outage one should...

Page 11: ...stable Wrench Tube 100 Silicone Grease 4 3 Installation Steps The Carbon filter has three openings the inlet the outlet and drain Open the water supply tap and flush the water pipe network to ensure w...

Page 12: ...he system to the plumbing leaving the system Water Line and Bypass Connection Once you have selected your location check the direction of the water flow in the main pipe A bypass valve system should b...

Page 13: ...gure below Wrap the threaded end of the flow controller with Teflon tape Tighten the two components of drain connector kit by hand Insert the drain connector kit onto the drain opening of the carbon f...

Page 14: ...MIN is displayed the value in minute increments MIN is displayed during Backflush the value displayed is the minutes of Backflush remaining 3 Colon double dots flashes as part of the time display It...

Page 15: ...minutes will reset to zero when the hours are changed 2 Backwash Duration Press Backwash Duration to display and set the current backwash cycle steps The value in minutes will be displayed for five se...

Page 16: ...hed for five seconds the controller returns to normal operation mode Pushing the Backflush button immediately returns the controller to normal operation Quick Cycling Press and hold for three seconds...

Page 17: ...ck the Troubleshooting section Initial Power Up Display When the camshaft has reached the HOME service position the display will show If the time of day alternating with filtered water volume is displ...

Page 18: ...placed into operation Please review MANUALLY INITIATING A CLEANING CYCLE before attempting startup 1 With the supply water for the system still turned off position the bypass valve to the not in bypas...

Page 19: ...owner s installation manual Follow all safety guidelines in the manual If metal pipe was used did you restore the electrical ground Securely install drain hose to an approved drain Perform a leak tes...

Page 20: ...or Diagnosis and Troubleshooting System Error Codes Problem Possible Cause Solution Flowing or dripping water at drain after cleaning cycle Debris is preventing 3 or 4 valve disc from closing Remove d...

Page 21: ...ce position Camshaft is not turning during E3 display Check that motor is connected Verify that the motor wire harness is connected to motor and controller module Verify that optical sensor is connect...

Page 22: ...ntair will deem the warranty to have expired and charge the relevant fees 4 Warranty will be void in the following conditions Installation by personnel who are not authorized by the Pentair Product ma...

Page 23: ...______________________________________________________________________ 7 MAINTENANCE RECORDS ___________________________________________________________________________________________________________...

Page 24: ...67685900 Thialand 16 Floor The Ninth Towers Grand RAMA 9 Tower B 33 4 Rama 9 Road Huaykwang Bangkok 10310 Thailand Tel 662 1681092 Philippines 5th Floor MAIA Suites 1747 Nicanor Garcia Street Corner D...