background image

9

OPERATING INSTRUCTIONS FOR THE DIGITAL 90 SECOND TIMER 

AND SETTING FOR EXTERNAL TIMER OPERATION

Up & Down 
arrow Buttons

Red “ON” 
LED

LED Time 
Display

Continuous 
Run (C-RUN) 
Button

OPT Button

OP T

C- RU N

FORWARD / REVERSE TIMED MOVEMENTS:

You may control the length of the forward / reverse 
movement time of your cleaner by using the control 
pad on your Power Supply.  The optimal amount of 
seconds to set the forward / reverse movements is 
the amount of time for cleaner to move to the furthest 
points of your pool, (cleaner can no longer move 
forward) plus several seconds to rest before reversing. 
The timer automatically recalls your setting once 
movement time is set.

To Adjust Time:

 Press the Up facing Arrow Button 

once for each additional second of movement you 
desire (up to 90 seconds) or the Down facing Button 
for less sec-onds (down to one second).

NOTE: As the cleaner moves across the pool, dirt can 
accumulate in the fi lter bag, reduce water fl ow and slow 
movement. Several seconds are needed in your setting to 
allow enough time for your cleaner to reach the furthest 
point of the pool before reversing.  Any additional seconds 
added while cleaner is operating are saved and automatically 
recalled with each subsequent use.

SET TIME:

1.  Turn the Power Supply Power Switch to  

    

the “ON” position.

2.  Adjust the timer (from 1-90 seconds).

3.  Press either the OPT Button or C-RUN.

Turn the Power Supply ON and wait a few seconds until the LED Ught fl ashes two horizontal bars in the LED Time 
Display. Make sure the GREEN light above the C-RUN Button is not blinking. If light is blinking, the timer is already 
set to the ExternalTimer Mode. If time is not blinking, it is currently set to the Internal 2·Hour Automatic Shut Off Timer 
Mode. Reset the Power Supply to the External Timer Mode by doing the following:

1. Press and release the C-RUN Button once. GREEN Light will illuminate.

2. Press and hold the C-RUN Button for approximately 5 seconds until the GREEN Light blinks. If blinking, the timer to 

    

the External Timer Mode is set.

Note: Power Supply will remain in the External Timer Mode until you physically reset it to the Internal Timer Mode; 
your 1 to 90 second Forward / Reverse digital time setting will not be affected. It will not reset to the Internal Timer 
Mode even if the power to the Power Supply is set to the OFF position.

 

Prowler

®

 710 Installation and User’s Guide

OPT Button

Ideal setting for frequent cleaner use.  In this setting your cleaner will Continuously Run until either the Power 
Supply is turned OFF or the Power Supply ‘ON / OFF Button’ is pressed “OFF” manually.  To restart your cleaner, 
either manually press the Power Supply ON / OFF Button or if Power Supply is connected to an external [separately 
purchased] automatic time control power source*, you can operate cleaner in the External Timed Mode. 

*Traditional external automatic time control power sources can be found at electrical and home renovation stores. Pool 
equipment specifc time control systems (control the cleaner’s Power Supply via a dedicated ‘relay’ connection) can be 
found at your pool retailer / builder.

C-RUN Button

Optimal setting for occasional cleaning. Cleaner will automatically turn off after 2 Hours of operation. 

ExtemalTimer Mode Set-Up:

Summary of Contents for Prowler 710

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide Prowler 710 Robotic Inground Pool Cleaner...

Page 2: ...nd brands and PentairWater Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others P N P12153 Rev C 3 30 11 Customer Service If you have quest...

Page 3: ...wler 710 Cleaner Works 4 Setting up your Prowler 710 Cleaner 5 Power Supply Transformer 5 Pool Cleaner with Floating Cable 5 Power Supply Set Up 6 Cleaner Placement 7 Adjusting the Timing Cycle 8 Oper...

Page 4: ...will create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Always disconnect...

Page 5: ...clean system is necessary for proper cleaner operation and coverage Before installing the cleaner fill the hose with water Always make sure the cleaner head is submerged and the hose is full of water...

Page 6: ...light or chemicals or parts which even if worn do not affect performance of the cleaner Nicks scratches fading discoloration etc are cosmetic conditions that do not affect mechanical performance Both...

Page 7: ...terlinesolongasthere is an adequate floor to wall angle most vinyl lined pools or radius of about 6 inches from beginning of radius to end most hard surface pools in 60 to 90 minutes or less Scrubs va...

Page 8: ...ional Features Time and energy saving features Reduces your filtration system s run time up to 25 Independently filters algae and bacteria Cleans and hydroscrubs along floors up inclines to the waterl...

Page 9: ...s cleaner has to offer NOTE Before setting up this product read and follow all warning notices and instructions starting on page ii Introducing the Prowler 710 Cleaner Congratulations on your purchase...

Page 10: ...s for easy vacuumingbythecleaner ssuctionpower Alldirtfromleavestoalgaeiscollectedintheinternalfilterbagfor easy removal A simple patented axle tilting system allows your cleaner to alternate between...

Page 11: ...gCable Power ON OFF Switch ResetButton NOTE ThePowerSupplyappearancemayvaryandfeaturesmaybelocatedindifferentpositionsthanwhatisshownabove Rear view Front view 6 Figure 1 B Pool Cleaner with Floating...

Page 12: ...so cause damage to property CAUTION Never power the cleaner ON if it is not fully immersed in water This cleaner has an internal timer which will automatically shut off the cleaner after 2 hours of op...

Page 13: ...ightsideupandallowittosinktothebottomofthepoolwiththe wheelsdown SeeFigure5 NOTE Yourcleanermustbecompletelysubmersedinthepoolwaterbeforeitisswitchedon Ifthe cleaner does not sink it is because air is...

Page 14: ...djusttheTimeControlDialaccordingly NOTE Turning the Time Control Dial clockwise will lengthen the time between reversals to a maximum time of 90 seconds Conversely turning the dial counter clockwise w...

Page 15: ...ight above the C RUN Button is not blinking If light is blinking the timer is already set to the ExternalTimer Mode If time is not blinking it is currently set to the Internal 2 Hour Automatic Shut Of...

Page 16: ...ime to clean the Filter Bag Removing the Cleaner from the Pool CAUTION Removing your cleaner by its Floating Cable may cause severe damage to the cable requiring costly repairs Keep the cleaner on all...

Page 17: ...he Bag in your hands to help removefineparticles Continuewringing cleaning and squeezing the Bag gently until rinse water is clear Use of a washing machine cold water only is recommendedwhenvisibledir...

Page 18: ...er Bag and cleaner After removing your cleaner from the pool you should clean and re install the Filter Bag Then rest your cleaner on all four wheels in a dry shaded area along with its Power Supply a...

Page 19: ...13 Prowler 710 Installation and User s Guide...

Page 20: ...oves quickly this is an indication that your Bag is not clean enough and you must repeat the cleaning instructions until the Bag is clean Water flow from the hydroscrub jet tubes Remove the Bottom Lid...

Page 21: ...debris like hair string or a small twig caught in the Propeller Use your paper clip to hook or free the debris and remove it Figure 20 on page 15 Reverses before reaching the opposite Turn the Time Co...

Page 22: ...16 Prowler 710 Installation and User s Guide Figure 17 Figure 18 Figure 19 Figure 20...

Page 23: ...Replacement Parts Prowler 710 Model 12 0 17 0 20 1 5 1 2 3 4 6 7 8 9 9 10 10 11 11 12 13 13 14 14 15 15 15 15 16 16 17 18 19 20 20 20 20 21 21 21 21 21 21 21 21 22 23 22 22 23 22 24 25 25 26 26 27 28...

Page 24: ...7 TUBE OVAL BRIGHT WHITE 3 x 1 58 O D 12 INC LG 1 18 TUBE OVAL WITH ONE HOLE 1 19 AXLE FIBER GLASS 16 5 INC LG 0 5 INC ROD 1 20 P12148 CLIP S S RETAINING STAR 8 21 WASHER NYLON FLAT 1 INC OD x 1 2 ID...

Page 25: ...19 Prowler 710 Installation and User s Guide Notes...

Page 26: ...20 Prowler 710 Installation and User s Guide Notes...

Page 27: ...21 Prowler 710 Installation and User s Guide...

Page 28: ...P N P12153 Rev C 03 30 11...

Reviews: