11 / 12
THERMAL MANAGEMENT SOLUTIONS
EN-RaychemWinterGardH900-IM-H53665 01/13
Note: The end seal is designed to be installed only once; it cannot be removed from the
heating cable once installed. Do not use until ready for final installation.
1 in
1A
2A
3A
2 in
1b
2b
3b
4b
• Cleanly cut off the
end of the cable.
• Score down and
around outer jacket 1
inch from the end.
• Remove the outer
jacket.
• Do not cut or damage
inner jacket.
• Unravel and remove
exposed braid.
• Firmly push end
seal onto the cable
(at least 1 1/2
inches). Some gel
may ooze out.
• Do not twist or try
to remove the end
seal during or after
insertion. Do not
reuse an end seal.
• Firmly push end seal
onto the cable (at least
1 1/2 inches). Some gel
may ooze out.
• Do not twist or try
to remove the end
seal during or after
insertion. Do not reuse
an end seal.
• Cleanly cut off the end
of the cable.
• Push the braid back 2
inches from the cable end.
• Slide the braid up
against the end seal
and secure with the
6-inch length of tape
provided.
End Seal for H612 and H622
End Seal for H311, H611, H621
H900 END SEAL