THERMAL MANAGEMENT SOLUTIONS
EN-RaychemWinterGardH900-IM-H53665 01/13
8 / 12
Outer jacket
Braid
Bus wires
Conductive core
Inner jacket
Braid
Bus wires
Conductive core
Inner jacket
WinterGard H311, H611, H621
Heating cables with braid and no outer jacket
WinterGard H612, H622
Heating cables with braid and outer jacket
Compression washer -
flat side up against
blue grommet
Blue grommet
6 3/4 in
6 in
1A
For H612 and H622 heating cables only
For all cables
2
3
7 in
1b
Note: Instructions generally show heating cable with braid and outer jacket.
Cables with no outer jacket look slightly different from those illustrated.
• Open sealing fitting and discard black grommet.
• Slide parts onto cable as shown.
• Push braid back to loosen slightly.
• Gently spread apart braid as shown.
• Bend heating cable and work it
through the opening in the braid.
• Lightly score completely around and then
down outer jacket.
• Bend heating cable to break jacket at
score; peel off outer jacket.
• Position braid on one side of heating cable.
• Straighten the braid and twist into a “pigtail.”
• Lightly score completely down and around the inner jacket.
• Bend heating cable to break jacket at score; peel off
inner jacket.
H900 pOWER cONNEcTION KIT
Identify heating cable
For H612 and H622 heating cables only