1 / 14
JBS-100-ECP-A
Combination power ConneCtion box and digital eleCtroniC Controller
installation instruCtions
IndustrIal Heat tracIng sOlutIOns
EN-RaychemJBS100ECPA-IM-H57463 05/16
JBS-100-ECP-A
with
Pyrotenax MI heating cable
using required MI cable
grounding kit
JBS-100-ECP-A
with
Raychem heating cable
Actua
l
Setpo
int
Temp
eratu
re
JBS-1
00-EC
P-A
Powe
r con
nectio
n box
and d
igital
electr
onic c
ontro
ller
Type 4
X
Input:
100-2
77 Va
c, 50
/60 H
z, 30 A
Outpu
t:
100-2
77 Vac,
30 A
Maxim
um A
mbie
nt:
140˚F
(60˚C
)
For m
ainta
ining
tem
peratu
res u
p to 4
25˚F
(220
˚C)
in no
nhaza
rdous
locati
ons.
Use
supp
ly wir
es su
itable
for a
t least
221˚F
(105
˚C).
Use
only w
ith cer
tified
Ray
chem
BTV,
QTVR,
XL-T
rac
e, XT
V and
VPL
heatin
g cab
les
and Raych
em ty
pe A &
D M
I heat
ing ca
bles
in
nonh
azard
ous lo
cati
on.
© 200
4-201
4 Pen
tair T
herm
al M
anage
ment
LLC
WW
W.PE
NTAIR
THER
MAL.C
OM
PN P
00000
0173
H
5749
6 0
5/14
Actua
l
Setpo
int
Temp
eratu
re
JBS-1
00-EC
P-A
Powe
r con
nectio
n box
and d
igital
electr
onic c
ontro
ller
Type 4
X
Input:
100-2
77 Vac,
50/6
0 Hz,
30 A
Outpu
t:
100-2
77 Vac,
30 A
Maxim
um A
mbie
nt:
140˚F
(60˚C
)
For m
ainta
ining
tem
pera
tures
up to
425˚F
(220
˚C)
in no
nhaza
rdous
loca
tions
.
Use su
pply
wires
suita
ble fo
r at le
ast 2
21˚F
(105
˚C).
Use
only w
ith certi
fied Ray
chem
BTV,
QTVR,
XL-T
race
, XT
V and
VPL
heatin
g cab
les an
d Raych
em typ
e A &
D M
I heat
ing cab
les in
nonh
azard
ous lo
cati
on.
© 20
04-201
4 Pen
tair T
herm
al Ma
nagem
ent L
LC
WW
W.PE
NTAI
RTHE
RMA
L.CO
M
PN P0
0000
0173
H
5749
6 05
/14
descrIptIOn
The Raychem JBS-100-ECP-A is an electric heat-tracing power
connection / electronic controller combination housed in a NEMA 4X
rated enclosure. It is designed for use only with Raychem BTV-CR,
XL-Trace, BTV-CT, QTVR-CT, XTV-CT, VPL-CT, KTV-CT, and Pyrotenax
MI heating cables in nonhazardous locations.
These kits may be installed at temperatures as low as −40°F (−40°C).
For easier installation store above freezing until just before installation.
The controller can be programmed to maintain temperatures of 425°F
(220°C). It operates at voltages from 100 to 277 Vac and can switch
current up to 30 Amps.
For technical support call Pentair Industrial Heat Tracing Solutions at
(800) 545-6258.
tOOls requIred
• Wire cutters
• Pliers or adjustable wrench
• Utility knife
• Large slotted screwdriver
• Needle nose pliers
• Small slotted screwdriver
• Wire stripper (for VPL-CT)
addItIOnal MaterIals requIred
• Pipe strap
• GT-66 or GS-54 fiberglass tape
• MI cable grounding kit (for MI cable installations)
Catalog No: MI-GROUND-KIT
• AT-180 aluminum tape
• Small pipe adapter (for 1 in (25 mm) and smaller pipes)
Catalog No: JBS-SPA
This component is an electrical device that must be installed
correctly to ensure proper operation and to prevent shock or fire.
Read these important warnings and carefully follow all of the
installation instructions.
• To minimize the danger of fire from sustained electrical arcing
if the heating cable is damaged or improperly installed, and to
comply with the requirements of Pentair Industrial Heat Tracing
Solutions, agency certifications, and the National Electrical
Code, ground-fault equipment protection must be used. Arcing
may not be stopped by conventional circuit breakers.
• Component approvals and performance are based on the use of
Pentair Industrial Heat Tracing Solutions-specified parts only.
Do not use substitute parts or vinyl electrical tape.
• The black heating cable core and fibers are conductive and can
short. They must be properly insulated and kept dry.
• Damaged bus wires can overheat or short. Do not break bus wire
strands when scoring the jacket or core.
• Keep components and heating cable ends dry before and during
installation.
• Use only fire resistant insulation materials, such as fiberglass
wrap or flame-retardant foam.
HealtH Hazard: Prolonged or repeated contact with the
sealant in the core sealer may cause skin irritation. Wash hands
thoroughly. Overheating or burning the sealant will produce
fumes that may cause polymer fume fever. Avoid contamination
of cigarettes or tobacco. Consult MSDS VEN 0058 for further
information.
CHEMTREC 24-hour emergency telephone:
(800) 424-9300
Non-emergency health and safety information:
(800) 545-6258
.
WARNING:
CAUTION:
KIt cOntents
Item qty description
A 1 Lid
B
1
Wire cover
C
1
Box with electronics
D
1
Green/yellow tube
E
1
Core sealer (for use with Raychem heating cables only)
F
1
Battery connector
G
1
Stand with RTD
H
1
Cable lubricant (for use with Raychem heating cables only)
I
1
Cable tie
J
1
MI cable grounding kit (ordered separately; P000000279)
K
1
Plug (for use with MI cable installations only)
apprOvals
Nonhazardous locations
A
G
F
H
I
B
C
D
E
K
J
Actua
l
Setpo
int
Temp
eratu
re
JBS-1
00-EC
P-A
Powe
r con
nectio
n box
and d
igital
electr
onic c
ontro
ller
Type 4X
Input:
100-277 V
ac, 50/60 Hz, 30 A
Outpu
t:
100-277 V
ac, 30 A
Maxim
um
Amb
ient:
140˚F (6
0˚C)
For m
aintaining tem
peratures up to 425˚F (220˚C)
in nonhazardous locations.
Use sup
ply
wires suitable for at least
221˚
F (105˚C).
Use only w
ith certified Raychem
BTV
, QTVR, X
L-T
race, X
TV and V
PL
heating cables and Raychem
type A
& D M
I he
atin
g cab
les in
nonhazardous location.
© 20
04-20
14 Pe
ntair Th
erma
l Man
agem
ent L
LC
WW
W.PE
NTAIR
THERM
AL.
COM
PN
P00000
0173
H
574
96
05/
14
Ho
ld 3
Seco
nds
WARNING
Shock Hazar
d
ALARMS
/ ERRORS:
rtd E
rr
= Short
ed or Ope
n S
ensor
Hi Alr
= High
Alarm
Lo
Alr
= Lo
w Alarm
Do not
rem
ove
cover wh
ile ener
gized
Ne
pas
enl
ever
le couv
ert t
ant
que l
e
régu
lateur
est sous
tens
ion
TEM
PER
ATU
RE
Nex
t
MEN
U
Batte
ry
Conn
ectio
n
Up
Dow
n
ACTU
AL
SETPOINT
SET
TING
S:
1 - *F or *C
2 - S
et P
oint
3 - D
ead Band
4 - High Alarm
5 - Lo
w Alarm
JBS-100-EC-A
Digit
al Thermos
tat