IndustrIal Heat tracIng sOlutIOns
EN-RaychemJBS100ECPA-IM-H57463 05/16
5 / 14
5/8 in
(15 mm)
Make sure the bus
wires do not kink,
bunch, or crossover
1/2 in
(13 mm)
1/2 in
(13 mm)
1 in (25 mm)
6
8
10
11
Tubes
Make sure all strands
go into the tubes.
7
9
• Mark the jacket
as shown.
• Push core sealer onto the
heating cable to the mark
made in Step 6.
note: Extra force may be
required for larger cables or
at lower temperatures.
• Slip the green/yellow tube onto the braid.
Heat-shrinking is not required.
• Trim bus wires and braid.
• If needed, re-twist and straighten bus wires,
then insert into the guide tubes as shown.
• Remove the guide tubes and
dispose of them in a plastic bag.
• Pull heating cable back into stand so 1 in (25 mm) is
exposed as shown. Use cable lubricant if needed.
caution: Health Hazard.
Wash hands after contact with sealant. consult
material safety data sheet ven 0058.