14-Slot AdvancedTCA Shelf
Maintenace
11596-100/-101/-102/-103
www.a-tca.com / www.schroff.biz
30
R1.1, July 23, 2008
4.6 Shelf Alarm Display (SAD) Replacement
Figure 19: Shelf Alarm Display (SAD)
Remove:
1 Unscrew both fixing screws (2).
2 Pull out Shelf Alarm Display (1).
Note:
Pull at both fixing screws (2).
Install:
1 Insert the guides (3) of the Shelf Alarm Display into the slots (4) of the
Horizontal board.
2 Insert the Shelf Alarm Display.
3 Tighten both fixing screws (2).
Torque: 0.67 Nm (6 in.-lb.)
Danger of electrostatic discharge!
Static electricity can harm delicate components inside the Shelf. You must
wear an ESD wrist strap before exchanging any part or electric component!
12706852
1
Shelf Alarm Display
3
Guides
2
Fixing Screws
4
Slots