14-Slot AdvancedTCA Shelf
Shelf Installation
11596-100/-101/-102/-103
www.a-tca.com / www.schroff.biz
12
R1.1, July 23, 2008
3.2 Rack-Mounting
This ATCA 14-slot Shelf can be installed in 19“ equipment racks. The rack must
be accessible from the front and rear for equipment installation.
Mounting brackets and cable trays come with the system. Allow sufficient
clearance around the rack for system maintenance.
Warning!
Do NOT move the Shelf by yourself. Due to the height and weight of the Shelf,
at least two persons are needed to accomplish this task. We recommend to
use a mechanical lift or remove all hot-swappable equipment for weight
reduction.
Warning!
Do NOT stack the Shelf on top of any other equipment. If the Shelf falls, it can
cause severe bodily injury and damage the equipment.
Caution!
Do NOT remove the Transportation Locks (See Fig. 1) before the Shelf is
completely fixed in the rack.
Caution!
Do NOT use the Fan Tray and PEM handles or cable trays as lifting points.
Danger of electrostatic discharge!
The Shelf contains static sensitive devices. While handling the Shelf you must
wear an ESD wrist strap to prevent static damage.