LEGEND® PLATINUM INSTALLATION MANUAL
D. Installing the Twist Lock Pressure
Relief Valve (Wall Fitting)
1. Take out any existing pool cleaner and/or wall
fitting.
2. Turn on the filtration pump and booster pump,
flush out the plumbing line.
3. Turn off filter pump and booster pump.
4. Remove the Wall Adapter from the Wall Fitting
and screw Adapter by hand into the dedicated
line. Turn until tight.
WALL ADAPTER
INSTALLED
QUICK
LOCK
PEG
QUICK DISCONNECT
O-RING
5. Take the Wall Fitting and Twist Lock the Wall Fitting
into the Wall Adapter 1/4 turn and pull out, to a
snug fit. Once the Wall Adapter is secure, you
can now twist lock and unlock to remove Wall
Fitting with ease from the Wall Adapter.
3
E. Cutting the Feed Hose
The Hose assembly comes in 5 sections now
covering approximately 30 ft. of the pool, which
provides ample hose for most residential pools. The
Back-Up Valve is now 30 in. from the head cleaner
and should always remain this distance. For larger
pools
see #14
on page 6
for instructions on
Adding
Additional Feeder Hose.
1. Take Feeder Hose out of box (it will be
approximately 30 feet long). Before installing
the unit, you should lay the feed hose out straight
in the sun, (for one day if possible). The hose has
been curled up in the box and sometimes will go
around in a circle. If this happens, take the first or
second section of hose from the wall and reverse
it, (turn it around). You might have to reverse both
sections to correct the problem. Make sure the
feed hose is cut and installed properly.
2. Measure how deep your pool is by using your
telepole or the clear end of the feeder hose.
Cut the clear (soft) hose equal to the depth of your
pool. (Hint: the grate or domed main drain at
the bottom is usually the deepest point.)
Example: The clear (soft) hose is 10 ft. long, if the
pool is 8½ ft. deep, cut 1½ ft. off of the clear (soft)
hose. If the depth is greater than 10 ft., do not cut
the clear (soft) hose.
Deepest End of Pool
Telepole / Clear (Soft) Hose
Measure and Mark the Water Level
Main Drain