F
R
A
N
Ç
A
I
S
E
S
P
A
Ñ
O
L
®
Teel Pool Pump with
Integral Trap
Operating Instructions & Parts Manual
4RJ93, 4RJ94 and 4RJ95
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Form 5S4186
®
E
N
G
L
I
S
H
Printed in U.S.A.
09319
1100/379/VCPVP
Unpacking and Inspection
Handle with care. Check items received
against packing list to be sure that all
equipment has been received. Inspect
for shipping damage. If found, file
claim with carrier immediately.
IMPORTANT
SAFETY
INSTRUCTIONS
Always follow basic safety
precautions with this equipment,
including the following:
To reduce the risk
of injury, do not
permit children to use this product unless
they are closely supervised at all times.
This pump is for
use with
permanently installed pools and may
also be used with hot tubs and spas if so
marked. Do not use with storable pools.
A permanently installed pool is
constructed in or on the ground or in a
building such that it cannot be readily
disassembled for storage. A storable
pool is constructed so that it may be
readily disassembled for storage and
reassembled to its original integrity.
SAVE THESE
INSTRUCTIONS
READ AND
FOLLOW SAFETY
INSTRUCTIONS!
This is the safety alert symbol.
When you see this symbol on your
system or in this manual, look for one of
the following signal words and be alert
to the potential for personal injury.
Warns about
hazards that will
cause death, serious personal injury, or
major property damage if ignored.
Warns about
hazards that can
cause death, serious personal
injury, or major property damage if
ignored.
Warns about
hazards that will or
can cause minor personal injury or
property damage if ignored.
NOTE:
Indicates special instructions
not related to hazards.
Carefully read and follow all
safety instructions in this manual
and on equipment.
Keep safety
labels in good condition; replace if
missing or damaged.
4RJ93
1
15.3/7.6
115/230
1
60
3450
230V
2”
2”
14
7
⁄
16
”
10
23
⁄
32
”
25
1
⁄
2
”
37 lbs.
4RJ94
1
1
⁄
2
19.2/9.6
115/230
1
60
3450
230V
2
2
14
7
⁄
16
10
23
⁄
32
26
1
⁄
2
44
4RJ95
2
12.0
230
1
60
3450
230V
2
2
14
7
⁄
16
10
23
⁄
32
27
45
Specifications
Motor
N.P.T.
Max Load
Motor
Conn.
Suc.
Dis.
Dimensions
Model
HP
Amps
Volts
PH
Hz
RPM
for
Inlet
Out
H
W
L
Wt
Performance Chart
4RJ93
1
100
92
85
78
70
60
35
–
–
66’
4RJ94
1
1
⁄
2
–
120
113
106
98
90
74
53
30
75
4RJ95
2
–
–
–
126
118
108
88
63
45
78
Gallons of Water Per Minute at Total Feet of Head
Max.
Model
HP
25’
30’
35’
40’
45’
50’
60’
70’
75’
Head
Description
Teel self priming centrifugal pumps (Model Nos. 4RJ93, 4RJ94, and 4RJ95) with
extra large integral trap are for use with swimming pools and spas. Maximum
suction lift 10’. Models 4RJ93, 4RJ94 (1 and 1
1
⁄
2
HP) are equipped with 115/230V dual
voltage capacitor start motors. Model Number 4RJ95 (2 HP) is equipped with 230V
single voltage capacitor start motor.
Bodies are a blend of glass-reinforced, highly corrosion-resistant thermoplastic.
High flow, medium head, and quiet operation.