Electrical (Continued)

VOLTAGE

Voltage at motor must be not more
than 10% above or below motor
nameplate rated voltage or motor may
overheat, causing overload tripping
and reduced component life. If voltage
is less than 90% or more than 110% of
rated voltage when motor is running
at full load, consult power company.

GROUNDING/BONDING

Install, ground, bond, and wire motor
according to local or National Electrical
Code requirements.

Permanently ground motor. Use green
ground terminal provided under

motor canopy or access plate (See Fig.
2); use size and type wire required by
code. Connect motor ground terminal
to electrical service ground.

Bond motor to pool structure. Use a
solid copper conductor, size No. 8
AWG (8.4 sq.mm) or larger. Run wire
from external bonding lug (See Fig. 2)
to reinforcing rod or mesh.

Connect a No. 8 AWG (8.4 sq.mm) solid
copper bonding wire to the pressure
wire connector provided on the motor
housing and to all metal parts of the
swimming pool, spa, or hot tub and to
all electrical equipment, metal piping
or conduit within 5 feet (1.5 m) of the
inside walls of swimming pool, spa, or
hot tub.

WIRING

Pump must be permanently connected
to circuit. The Wiring Chart below
gives correct wire and circuit breaker
sizes for the pump alone. If other
lights or appliances are also on the
same circuit, be sure to add their amp
loads to pump amp load before
figuring wire and circuit breaker sizes
(If unsure how to do this or if this is
confusing, consult a licensed
electrician). Use the load circuit
breaker as the master on-off switch.

AWG WIRE SIZE

1

115/230/1

15.3/7.6

20/15

12/14 

8/14

6/14

6/12

4/10

1

1

/

2

115/230/1

19.2/9.6

25/15

10/14

8/14

6/12

4/10

4/10

2

230/1

12.0

20

14

14

12

10

10

WIRING CHART – RECOMMENDED WIRE AND FUSE SIZES

Max. Load

Branch Fuse*

Distance in Feet from Motor to Supply

Motor HP

Volts/Ph

Amp

Rating Amps†

0 - 100 

101 - 200 

201 - 300 

301 - 400 

401 - 500 

(*) Fusetrons are recommended instead of fuses on all motor circuits

(†) At 115/230V

Figure 2 – Typical ground screw and
bonding lug locations.

Figure 3 – Wiring hook-up diagram

Bonding

Lug

Green

Ground

Screw

White 

230
Volt
Lines

A

B

L2

L1

Blue

SINGLE

VOLTAGE

MOTORS

DUAL

VOLTAGE

MOTORS

A

B

L2

L1

White
w/Black 
Tracer

Black

115
Volt
Lines

A

B

L2

L1

White
w/Black 
Tracer

Black

230
Volt
Lines

Motor Terminal Board Connections

WARNING

Hazardous voltage. 
Can shock, burn, or 
cause death.

Disconnect power to motor
before working on pump or
motor.

Ground motor before 
connecting to power supply.

Summary of Contents for Teel 4RJ93

Page 1: ...this symbol on your system or in this manual look for one of the following signal words and be alert to the potential for personal injury Warns about hazards that will cause death serious personal inj...

Page 2: ...icing pump and piping NOTE When connecting threaded pipe directly to pump use Teflon tape or Plasto Joint Stik1 to seal connections Do not use pipe dope pipe dope causes cracking in some plastics and...

Page 3: ...ystem must be six feet per second or less even if one main drain suction fitting is com pletely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specifi cation...

Page 4: ...walls of swimming pool spa or hot tub WIRING Pump must be permanently connected to circuit The Wiring Chart below gives correct wire and circuit breaker sizes for the pump alone If other lights or ap...

Page 5: ...Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTE Tighten trap cover by hand only no wrenches Pump should prime now Priming time will dep...

Page 6: ...wer to motor before working on pump or motor Aside from lubricating trap cover O Ring no lubrication or regular maintenance is needed beyond reasonable care and periodic cleaning of strainer basket If...

Page 7: ...tion to jurisdiction LIMITATION OF LIABILITY To the extent allowable under applicable law Dayton s liability for consequential and incidental damages is expressly disclaimed Dayton s liability in all...

Page 8: ...94 WG 17 16 18 19 20 21 22 23 15B 1 2 3 4 5 6 7 8 8A 8B 9 10 See Box A Se Bo 11 12 13 14 15A Please provide following information Model number Serial number if any Part description and number as shown...

Page 9: ...85P C3 185P C3 185P 1 13 Trap cover O Ring U9 375 U9 375 U9 375 1 14 Trap basket C8 58P C8 58P C8 58P 1 15A Drain plug U178 920P U178 920P U178 920P 2 15B 5 16 14 x 5 8 Mounting screw 2 16 Base C4 77P...

Page 10: ...rap and strainer trap or impeller 2 Impeller is clogged 2 Check impeller for clogging Follow steps 1 trough 7 under Removing Old Seal Page 6 Follow steps 7 through 11 under Installing a New Seal Page...

Reviews: