background image

Component

Check/Interval

Remarks

Warning 

picto-

grams

Visual 

check/

Monthly

Replace if necessary

Water supply

Check lines and con-
nections/Monthly

Replace  any  dam-
age immediately

Safety devices

Visual 

check 

Monthly

Ensure  correct  in-
stallation/ refitting

General  condition 
of pumps 

Visual 

check/Half-

yearly

Look out for any cor-
rosion or damage

Cooling ribs of elec-
tric motors

Clean  the  cooling 
ribs to maintain the 
cooling effect/ Half-
yearly

Electrical 

equipe-

ment

Check/Monthly

Rectify  loose  con-
nections  or  singed 
cables  immediately. 
HAve  all  faults  re-
paired by a qualified 
electrician

Preliminary 

filter 

housing

Check 

housingfor 

dirt/Weekly

Remove 

all 

dirt 

thoroughly

O-Ring  in  prelimi-
nary filter cover

Visual  check  /  Half-
yearly

Customer service

HERENTALS, BELGIUM (8:30 A.M. to 4:30 P.M.) CETP
Website: www.pentairpooleurope.com

Declaration of Conformity

Standards used for showing compliance with the essential re-
quirements in the directive 2006/42/EC:

• 

EN60335-1, 

• 

EN60335-2-41

The  manufacturer,  Pentair  has  the  right  to  modify 
the  products  without  previous  notice  for  as  far  as 
theic rharacteristics are not really changed by this.

© 2012 Pentair. All rights reserved This document is subject 
to change without noticeTrademarks and disclaimers: Ultra-
Flow®, WhisperFlo®, SuperFlo®, Challenger® ® and Pentair are 
trademarks  and/or  registered  trademarks  of  Pentair  and/or 
its affiliated companies. Unless noted, names and brands of 
others  that  may  be  used  in  this  document  are  not  used  to 
indicate an affilitation or endorsement between the propri-
etors of these names and brands and Pentair. Those names 
and brands may be the trademarks of those parties or others.

IMPORTANT SAFETY PRECAUTIONS

THESE  OPERATING  INSTRUCTIONS  CONTAIN  IMPORTANT 
INFORMATION ON THE SAFE, PROPER AND ECONOMICAL 
OPERATION  OF THE  SWIMMING  POOL  PUMP.  STRICT  OB-
SERVATION OF THE OPERATING INSTRUCTIONS WILL HELP 
TO  AVOID  DANGERS,  REDUCE  REPAIR  COSTS  AND  SHUT-
DOWN TIMES AND INCREASE THE RELIABILITY AND WORK-

ING LIFE OF THE PRODUCT.

SECTION 1. GENERAL INFORMATION

Check carton for any evidence of damage due to rough han-
dling  in  shipment.  If  carton  or  any  pump  components  are 
damaged, notify the carrier immediately.
Failure to follow the safety instructions may result in serious 
adverse health effects, or even serious or fatal injury. Failure 
to follow the safety instructions will in all cases invalidate all 
guarantees and liability on the part of the manufacturer.

• Avoid dry run of the pump, as long as the pump is not filled   
  with water;
• This pump is equipped with a mechanical seal.
• Damage to shaft seal could be the cause by non-observance  
  of instructions.
• Please follow instructions for filling up the pump according  
  to installation and instruction manual.

SECTION 2. APPLICATION

Only to be used to circulate swimming pool water.

SECTION 3. INSTALLATION 

• Install the pump as near to the pool as practical.
• Use a direct and short suction line with continuous slope in  
  order to avoid long priming times.
• The pump should be placed on a flat solid foundation, high  
  enough to prevent flooding of the motor. 

• Install the filter and pump in a sheltered location, ensuring  
  ventilation and adequate access for servicing.
• Do not mount electrical controls directly over pump.
• Provide adequate floor drainage to prevent flooding. 
• Size all piping adequately and keep the number of elbows  
   to a minimum.
•  Independently  support  the  pipe  near  the  suction  and  dis 
     charge of the pump in order to reduce the strain on the pump. 
•  Avoid  overtightening  pipe  connections.  Use  only  pipe  
    sealants  formulated  for  plastics.  Do  not  use  petroleum     
    based products. It is essential that the suction line is free of  
    air leaks. The suction line should always be at least the same  
    size as the suction inlet of the pump.
• Fitting a non-return valve after the pump on the installation
    will prevent the impeller from unwinding and is strongly
    recommended.

SECTION 4. START / OPERATION

Starting the pump
• Fill pump strainer with water to suction pipe level.
•  Lubricate  the  lid  Oring  with  lubricant  each  time  it  is  
removed. 
• Energize the motor, the pump will prime. The priming time 
depends  on  the  suction  lift  and  distance  to  the  pool.  Five 
minutes is a reasonable time. 
•  Pump  will  not  lift  more  than  2,5  meter.  If  pump  does  not 
prime, see troubleshooting guide.

Maintenance

The strainer basket should be weekly removed and cleaned. 
Never operate the pump without its strainer basket.

Winterizing

• Protect the pump from freezing.
• Remove all plugs and drain the pump and all piping. 
• Store drains and plugs in the strainer basket.
• Remove the pump to a dry and warm room. 
•  Do  not  wrap  the  motor  with  plastic  covering  as  
   condensation may damage the pump. 
• In installations where the pump can not be drained, a 40%  
   propyleneglycol, 60% water solution will protect to -46°C. 
• Do not use other anti-freeze solutions, these are all highly  
   toxic and will damage the pump.