598-1351-01

Mount the Light Control

  Align the light control cover plate and cover plate 

gasket. Secure with the mounting bolt.

  Align the three slots in the decorative shell with the 

lamp holder pins. Push the shell in and then twist 
clockwise to lock. Repeat for other shell.

Lock Nut

To  avoid  water  damage  and 
electrical  shock,  keep  lamp 
holders 30° below horizontal.

❒ 

Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from the factory setting. When screwing in the flood 
lamps, do not overtighten.

Keep lamps at least 
1"  (2.5  cm)  from 
both sensors. Do not 
allow  the  lamps  to 
block either lens.

Lens

  Push the rubber plug firmly into place.

  If a wet location junction box was not used, caulk 

the  wall  plate  mounting  surface  with  silicone 
weather sealant.

Shell Slot

Black to Black

White to White

Gasket

Connect any fixture ground wire(s) to the junction 
box ground wire.

Wire the Light Control

Rubber Plug

Mounting 

Bolt

 WARNING: Turn  power  off  at  circuit  breaker 

or fuse.

❒ 

Remove the existing light fixture.

❒ 

Install mounting strap to junction box using screws 
appropriate for your junction box.

  The plastic hanger can be used to hold the fixture 

while wiring. The small end of the plastic hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.

  Thread all fixture wires through the large holes in 

the gasket as shown.

  Connect the junction box wires to the light fixture 

wires as shown. Twist together and secure with 
wire connectors.

Summary of Contents for MSL360FWPB

Page 1: ...ors This package includes 6 Screws 3 sizes included OPERATION resets to Auto Mode at dawn TEST 10 5 1 TEST ON TIME Put the ON TIME switch on the bottom of the sensors in the TEST position MANUAL MODE...

Page 2: ...For under eave installation the sensor heads must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For second story installation point one senso...

Page 3: ...ace If a wet location junction box was not used caulk the wall plate mounting surface with silicone weather sealant Shell Slot Black to Black White to White Gasket Connect any fixture ground wire s to...

Page 4: ...inute warm up period beforetheywilldetectmotion Whenfirstturned on wait 1 1 2 minutes Bottom of Sensor Avoid aiming the control at Objects that change temperature rapidly such as heating vents and air...

Page 5: ...ct or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or retu...

Page 6: ...ENTO Se pone en Autom tico al amanecer Para MODO MANUAL pr ndalo 1 segundo APAGADO luego Para AUTOMATICO Para PRUEBA Nota Cuando lo prenda por primera vez espere 1 1 2 minutos hasta que el circuito se...

Page 7: ...tro de la uni n esf rica Ajuste el tornillo sujetador cuando termine Apriete el tornillo sujetador cuando termine S lo para montaje el ctrico Oscile los cabezales de los detectores hacia la uni n del...

Page 8: ...se us una caja de empalme para sitio mojado calafatee la superficie de montaje de la placa de pared con un sellador de silicona contra la intemperie Blanco a blanco Negro a negro Empaquetadura l mina...

Page 9: ...na dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales dom sticos o el tr fico puedan activar el control Los objetos grandes cercanos y de colores res plandecientes...

Page 10: ...uehacequeelcaloractiveeldetector Reposicione la l mpara lejos del detector o de los objetos cercanos 2 El control de luz est apuntando hacia unafuentedecalortalcomounconducto de aire de secadora o hac...

Page 11: ...nstalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de garant a SERVICIO T CNICO Favo...

Page 12: ...rend Mod le MSL360FWPB Commande d clairage d tecteur de mouvement Conforme aux exigences ENERGY STARMD lorsquevousutilisezunelampe de 120 W maximum FONCTIONNEMENT Revient au mode automatique au lever...

Page 13: ...on Pour montage sous avant toit seulement Faites pivoter le capteur en direction de la vis de la bride Faites ensuite tourner le capteur de 180 de sorte qu il soit plac face au sol Pour une installati...

Page 14: ...ement en place Si vous ne pouvez pas utiliser une bo te de jonction pourmilieuhumide calfeutrezlasurfacedemontage de la plaque murale avec un scellant silicone C blage De La Commande D clairage Raccor...

Page 15: ...ds objets clairs proximit qui r fl chissent la lumi re du jour et risquent de d clencher le dispositif d arr t Ne pas pointer d autres appareils d clairage vers le d tecteur 21 m 2 4 m D tecteur Mouve...

Page 16: ...les protecteurs de lampes ont t install s GARANTIE LIMIT E DE 2 ANS Il s agit d une Garantie limit e qui vous conf re des droits juridiques sp cifiques Vous pouvez galement jouir d autres droits varia...

Reviews: