2.2
Jumper and Switch Settings
The following sections describe user operating parameters that are set by shorting
jumpers or DIP switches on the Model 78741.
The shorting jumpers used on the Model 78741 are for 0.020" (0.51 mm) square pins
spaced on 0.079" (2.00 mm) centers. These jumpers are NorComp part number 810−
002−LP1R001, or equivalent. Pentek’s part number for these jumpers is 356.00015.
The Model 78741 includes one Pentek 71741 XMC module mounted on a Pentek Model
7807 XMC to PCI Express (PCIe) carrier as illustrated in
on the prior page.
As shipped, the 71741 XMC module is mounted onto the PCIe carrier.
As shipped from the factory, all jumpers and DIP switches are installed in default posi−
tions on your board. The default operating parameters selected may or may not meet
your requirements. Before installing your Model 78741, please review the following
sections to determine whether you need to change any of these settings.
Refer to
for the switch settings on the Model 71741 PCB. All switch
blocks are accessible in this shipped configuration. Refer to
for the
jumper settings and
for the switch settings on the carrier PCB.
All switch blocks are accessible in the shipped configuration. If you need to access
certain jumpers on the PCIe carrier, you must first remove the XMC module from
the PCIe carrier, as described in
Note
Do not change jumpers or switches that are not described in this chapter—
those are reserved for factory test and setup purposes only.