5.4
Auxiliary power
5.5
Ambient conditions
5.6
Process conditions
Electrical connection
Cable access M20 x 1.5
with internal terminal block
V1-plug (optional) see section 6.4
Protection class
III
Electrical protection methods
Reverse polarity protected,
lightning protection,
short circuit protection.
Power supply
12 V ... 36 V
12 V ... 30 V (external versions)
Ambient Temperature
– 40 °C ... + 85 °C
(– 20 °C ... + 70 °C with display)
Storage Temperature
– 40 °C ... + 85 °C
(– 35 °C ... +80 °C with display)
Climate Class
D per DIN IEC 654-1
Protection class per EN 60529
IP65 (IP67 upon request)
EMC per
EN 50081-2, EN 50082-2,
NAMUR NE 21
A maximum cleaning temperature of 100 °C can be used for devices
installed within hazardous areas.
Temperature of medium depending on
sensor
Standard devices
Devices for food applications
Devices for oxygen applications (oil-free)
– 30 °C ... + 100 °C
– 10 °C ... + 100 °C
– 30 °C ... + 60 °C
Maximum cleaning temperature
120 °C, max. 10 min.