Operation
2597
78 2013-
02
31
Setting the data format
1. Select
Read/Write > Write data > Options > Data format
.
2. Press the Enter navigation button to select the required data format (
).
3. Press the left selection button to confirm your selection (
)
4. Press the right selection button to exit the options (
).
Transferring data to data carriers
To transfer data to data carriers, proceed as follows:
1. Select
Read/Write > Write data > Data
.
One or more data input fields are displayed (the number of data input
fields displayed is based on the number of blocks.)
2. Navigate to the individual data input fields using the up navigation button
(
) and the down navigation button (
).
3. Enter the required data with the correct syntax for the selected data format
using the input buttons.
4. Press the CLEAR input button to delete individual characters (
). In
principle, you can only delete the character last entered, not individual
characters within the string.
5. Press the left selection button to confirm your entry (
).
If the format of the entered characters differs from the specified data
format, a fault message is issued and the value is not adopted.
6. Position the read/write head on the handheld device directly in front of the
data carrier.
HEX
(hexa-
decimal)
In hexadecimal data
format, numbers 0 to 9
and letters A to F are
available.
01
xx xx xx xx
(spaces are not
required)
11 22 11 22
02
xx xx xx xx
xx xx xx xx
11 22 11 22
1A 2B 3C 4D
03
...
DEC
(decimal)
In decimal data format,
numbers 0 to 255 are
available.
01
xxx xxx xxx xxx
(spaces are not
required)
111 222 111
222
02
xxx xxx xxx xxx
xxx xxx xxx xxx
111 222 111
222
010 020 030
040
03
...
Data
format
Notes
Block quantity
(maximum 32) Format
Example