Software description PF_Ident
2597
78 2013-
02
99
9.3.15
IP* Read/Write Heads
Operating frequency: 125 kHz.
Settings > Password
For further information on
Password mode
, see see chapter 10.5
Password submenu
Description of Menu Entries
PSW mode
In the
PSW mode
menu entry, you have the option of activating or deactivating
password mode.
In password mode, the password is transferred to the data carrier every time a
command is issued. If a data carrier is activated with an incorrect password,
accessing data areas without write protection is no longer possible.
Activating/Deactivating Password Mode
1. Select
Password
.
2. To activate or deactivate password mode, press the "Enter" navigation button
(
).
Password
In the data input field of the
Password
menu entry, you have the option of
assigning a password.
The default password for the read heads and the data carriers is 00000000
(hexadecimal format) on delivery. The password in the read/write head is
temporary and the password in the data carrier is permanent, which means that
the password in the read/write head is deleted if the power supply is interrupted.
The value range for password entry is 00000000
h
...FFFFFFFF
h
.
Submenu
--
Menu entry
PSW mode
Password [ASCII]