Description
The handheld reader is designed to be used in explosion-hazardous areas. For proper opera
-
tion in explosion-hazardous areas, the permissible RS-232 cordsets CBL-IDMx60-D-J1-S*
must be used. The intrinsically safe power supply and data transfer are realized via this cable.
An accessory cable DATL-IDM-DB-S-XX00-N0 is required for a connection to the VisuNet GXP
in the AG-XX00 housing. This provides the housing feedthrough and has a connection socket
that fits the scanner connection cable.
4.6
IDM-Z2-160-D-J2-SU-* System Structure 5
Overview of the complete system structure 5: Wired 1-D handheld reader IDM-Z2-260-D-2D-
J2-S1-N-N0 connected to the power module and the USB Ex i interface "4" of the VisuNet GXP.
Figure 4.6
Required Components:
•
VisuNet GXP system with interface "4"
•
DATL-IDM-DB-S-XX00-N0 connection cable VisuNet GXP interface
•
CBL-IDMx60-D-J1-S* barcode reader connection cable
•
IDM-Z2-260-D-2D-J2-S1-N-N0 2-D barcode reader
•
SCANNER-HOLDER-U1-XX00-N0
Note
The installation of the IDM-Z2-160-D-1D-J2-SU-N-N0 and IDM-Z2-160-D-1D-J2-SU-P-N0
barcode reader to the integrated barrier of the VisuNet GXP requires the optional interface "3".
Refer to the VisuNet GXP technical data (Module A and B) for further information regarding the
interfaces.
Warning!
Zone 2/22 VisuNet GXP system installations are only suitable for use in explosion group IIB.
Z2 Barcode Reader, connection to VisuNet GXP via interface "4"