IUH-F117-V1-*
Commissioning
20
13
-0
4
27
Example:
In the examples below, the read/write head is connected to channel 1 of the
control interface.
Reading Tags
Enhanced Read Read-Only Code
Send the enhanced read read-only code command to the read/write head. The
LEDs on the read/write head flash green.
Move a tag into the read/write head's measurement range. When the tag has
been detected and the read-only code has been read out, the LED on the
read/write head turns yellow. The read-only code is displayed in the terminal
program.
Describing Tags
Single Write Special Read-Only Code
Send the single write special read-only code command to the read/write head
while a tag is in the measurement range. see "Single Write Special Read-Only
Serial
Ethernet
PROFIBUS
Command:
EF1
.00.04.1D.03
.1D.03
Confirmation:
-
.00.06.1D.03.FF.0B
.1D.03.FF.0B
Response:
.35.31
.00.06.1D.03.05.0C
.1D.03.05.0C
Table 6.1
Enhanced read read-only code, no tag in the measurement range
Serial
Ethernet
PROFIBUS
Response:
.30.31.E2.04.2
6.70.18.01.00.
00
.00.0E.1D.03.00.37.E2.0
4.26.70.18.01.00.00
.1D.03.00.37.E2.04.26.7
0.18.01.00.00
Table 6.2
Enhanced read read-only code, tag is entering the measurement range
Serial
Ethernet
PROFIBUS
Command:
SP1E.30.00.11
.22.33.44.55.6
6.77.88.99.AA.
BB.CC
.00.14.0D.E3.00.00.30.0
0.11.22.33.44.55.66.77.
88.99.AA.BB.CC
.0D.E3.00.00.30.00.11.2
2.33.44.55.66.77.88.99.
AA.BB.CC
Confirmation:
-
.00.06.0D.E3.FF.2D
.0D.E3.FF.2D
Response:
.30.31
.00.06.0D.03.00.2E
.0D.03.00.2E
Table 6.3
Single write special read-only code, tag is in the measurement range