IUH-F117-V1-*
Operation
20
13
-0
4
39
Channel Dense Reader Mode CD (EU version only)
This parameter sets the number and sequence of transmission channels
permitted in dense reader mode (DRM), or reads out the number and sequence
of permitted transmission channels. Transmission channels 4, 7, 10, and 13 are
available.
Example:
WP1UCD.00.04.07.0A.04.0D defines the sequence 7, 10, 4, and 13 as the
permitted transmission channels
WP1UCD.00.01.0A allows the read/write head to use only transmission channel
10
RP1UCD.00.00 reads out the sequence of permitted transmission channels
Reset to Default, RD
This parameter returns all settings of the read/write head to the default
configuration.
Example:
WP1URD.00.00
Note!
You can operate the IUH-F117-V1-* read/write head only with internally specified
transmission power. For the software, you can enter any transmission power
between 300 mW
erp
and 2000 mW
erp
or between 500 mW
eirp
and 4000 mW
eirp
using the command WP1UPT.00.02.xx.xx. The read/write head automatically sets
the transmission power to the next lowest value available. Any entries outside the
specified value range are returned as errors. Command RP1UPT.00.00 allows
you to read out the power value that is currently set.
ParamTyp:
CD
Default:
CD = .04.0A.07.0D
Value range:
4, 7, 10, 13
Tip
If you have parameterized several transmitting channels using the parameter CD,
the read algorithm automatically selects a suitable transmitting channel from the
available channels. see chapter 7.2.
ParamTyp:
RD