20
13
-0
4
46
IUH-F117-V1-*
Appendix
Ambient conditions
Mechanical specifications
11.3
Measurement Range
The maximum detection range of the read/write head in open areas is 6 m. The
specified maximum operating range in industrial areas is around 3 m. This
operating range represents a typical range and is determined by the tag used.
Other influencing factors include the design/installation of the specific application,
interference from any materials present (in particular metal), and the ambient
conditions. The read and write distances for the relevant tag, which are detailed
separately, have been established in a test laboratory under ideal conditions. For
this reason, the combination of read/write head and tag must be tested for the
intended application under real conditions.
Please note the distance tables. The distance tables and additional information
regarding your product can be found at http://www.pepperl-fuchs.com. Simply
enter the product name or model number in the
Search
box and then click the
Search
key.
Select your product from the list of search results. Click on the information you
require in the product information list, e.g.,
Documents
.
Standard conformity
Electromagnetic
compatibility
-
EN 301489-
1 V1.9.2:2011 ,
EN 301489-
3 V1.4.1:2003
EN 301489-
1 V1.9.2:2011 ,
EN 301489-
3 V1.4.1:2003
Safety
-
EN 60950-
1:2006/A1:2010
EN 60950-
1:2006/A1:2010
Protection degree
EN 60529:2000
EN 60529:2000
EN 60529:2000
Standards
-
EN 50364:2010
EN 50364:2010
Ambient
temperature
-25 ... 55
°
C (-13 ... 131
°
F)
Storage temperature -25 ... 85
°
C (-13 ... 185
°
F)
Protection degree
IP54
Connection
M12 x 1 connector
Material
Housing
aluminum / ABS
Mass
approx. 3.1 kg