Safe Position Detection with PCV100-F200-B17-V1D-6011
Installation
2
017-
08
11
Orientation of Master Reader
Position the master reader at an angle of 0
°
in relation to the code tape. If the text on the back of
the reader can be read from the same direction as the text on the code tape, the reader is in the
correct position.
The corresponding value must be specified in the module parameters.
Figure 3.6
Orientation of the master read head
Orientation of Control Reader
Position the control reader at an angle of 180
°
in relation to the code tape. When the position is
correct, the text on the code tape appears on the reader if the text on the back of the reader is
legible.
Define the corresponding value in the module parameters.
Figure 3.7
Orientation of the control read head