Installation
2
0
1
6
-0
9
29
3.3
Electrical Connection
The reader is connected electrically via an 8-pin M12 x 1 connector on the side of the housing.
The power is supplied via this connection. The configurable inputs and outputs on the reader
are located at this connection.
Figure 3.23
Figure 3.24
Color Assignment
Fuchs single-ended cordsets (female) are manufactured in accordance with
EN60947-5-2. When using a type V19-... () female cordset with an open cable end on the
Main
connection, the colors are assigned as follows:
Shielding Cables
The shielding of connection lines is required to suppress electromagnetic interference.
Establishing a low resistance or low impedance connection with the conductor or equipotential
bonding circuit is a particularly important factor in ensuring that these interference currents do
not become a source of interference themselves. Always use connection lines with braided
shield; never use connection lines with a film shield. The shield is integrated at both ends, i.e.,
in the switch cabinet or on the controller
and
on the read head. The grounding terminal
available as an accessory allows easy integration in the equipotential bonding circuit.
Connector Assignment
Connection pin
Strand color
Color abbreviation
1
White
WH
2
Brown
BN
3
Green
GN
4
Yellow
YE
5
Gray
GY
6
Pink
PK
7
Blue
BU
8
Red
RD
1
2
3
4
5
6
7
8
INPUT_SELECTION_DIR_RIGHT
+ UB
USB_DM
USB_DP
OUTPUT_LANE_PRESENT
INPUT_SELECTION_DIR_LEFT
-UB
IN/OUT 3
M
a
in
1
4
6
7
8
5
3
2
Main