2
0
1
6
-0
9
38
Commissioning
Activating Parameterization Mode
1. Press button 2 on the rear of the reader and hold for longer than 2 seconds.
Yellow LED3 now flashes.
2. Hold the "ENABLE" code in front of the camera system on the reader to trigger final
activation
If the "ENABLE" activation code is detected, the green LED2 lights up for 1 sec. If the
activation code is not detected, LED2 lights up red for 2 seconds.
Parameterization
Place the parameterization code in the field of vision of the camera module.
After the parameterization code is detected, the green LED2 lights up for 1 sec. In the event
of an invalid parameterization code, LED2 lights up red for 2 seconds.
Exiting Parameterization Mode
Hold the "STORE" code in front of the camera system on the reader to save the configuration
When the "STORE" memory code is detected, the green LED2 lights up for 1 sec. The
parameterization is stored in the nonvolatile memory of the reader and parameterization mode
is terminated. Parameterization of the reader is now complete. If the memory code is not
detected, LED2 lights up red for 2 seconds.
4.3.1
Product documentation on the internet
Product/Key word search
box and click
Search
.
Select your product from the list of search results. Click on the information you require in the
product information list, e.g.,
Technical documents
.
A list of all available documents is displayed.
Note!
If you press button 2 briefly in parameterization mode, this mode is closed immediately. Any
parameter changes that are made but have not yet been saved are discarded. The reader
operates with the last valid parameters that were saved.
Note!
When the parameterization mode is activated, there is no data exchange via the bus.