Operation and communication
2
0
1
6
-0
9
47
Consumer Heartbeat Time
The monitored identifier guard ID results from the default identifier distribution: Guard ID =
0x700 + node ID
Producer Heartbeat Time
Identify Object
Index
Subindex
Description
Data type
Attribute
PDO mapping
possible
Default value
0x1016
0
Number of
Subsequent
Parameters
unsigned8
ro
no
40
1 ... 64
Consumer
Heartbeat
Time
1
1.Expected heartbeat cycle time [ms] and node ID of the monitored bus node
unsigned32
rw
no
0
Bit
31 ... 24
23 ... 16
15 ... 0
Reserved
1
1.Always 0
Node ID
Heartbeat Time [ms]
Index
Subindex
Description
Data type
Attribute
PDO mapping
possible
Default value
0x1017
0
Producer
Heartbeat
Time
1
1.Time [ms] between two sent heartbeat telegrams
unsigned16
rw
no
0
Index
Subindex
Description
Data type
Attribute
PDO mapping
possible
Default value
0x1018
0
Number of
Subsequent
Parameters
unsigned8
ro
no
4
1
Manufacturer
Identifier
unsigned32
ro
no
0x000000AD
2
Device
Identifier
unsigned32
ro
no
0
3
Version
Number
unsigned32
ro
no
0
4
Serial Number unsigned32
ro
no
0