Appendix
2
0
1
6
-0
9
69
Figure 6.4
The code card "USE" adopts the modified configuration in the
volatile
working memory
of the reading head and terminates external parameterization operating mode. The
reading head then operates with this configuration. However, if the reading head is
switched off and on again, the configuration is lost and the reading head operates with
the last valid configuration that was saved. This function is used primarily for test
purposes.
Figure 6.5
The code card "DEFAULT" restores the settings of the reading head to default and
terminates external parameterization operating mode.
6.3
Code Cards for Setting the Baud Rate
Parameterization allows you to assign various transfer rates to the reader for communication via
CANopen.
Figure 6.6
The code card assigns the 10 kBaud baud rate to the read head
Use
Default
Baud Rate: 10 kBaud