background image

PMI360DV-F130-3E2-V15
Inductive Angular 

Positioning System

Manual

Summary of Contents for PMI360DV-F130-3E2-V15

Page 1: ...PMI360DV F130 3E2 V15 Inductive Angular Positioning System Manual ...

Page 2: ...sion as well as the supplementary clause Expanded reservation of proprietor ship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs com North American Headquarters Pepperl Fuchs Inc 1600 Enterprise Parkway Twinsburg Ohio 44087 USA Phone 1 330 425 3555 E mail sales us pepperl fuchs com Asia Headquarters Pepperl Fuchs Pte Ltd P F Bu...

Page 3: ...ection Cables 9 4 3 2 Actuator 9 5 Installation 10 5 1 Note on safety 10 5 2 Mounting 10 5 3 Electrical Connection 12 6 Commissioning 14 6 1 Programming the Switching Outputs 14 7 Output Logic during Normal Operation 17 8 Function of Switching Outputs S1 S2 and S3 18 9 Maintenance and Repair 19 9 1 Maintenance 19 9 2 Resetting the Output Functions to the Factory Setting 19 10 Troubleshooting 21 10...

Page 4: ... worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the device its functions or accessories please contact us at Pepperl Fuchs Group Lilienthalstraße 200 68307 Mannheim Germany Telephone 49 0 621 776 1111 Fax 49 0 621 776 271111 Email fa info de pepperl fuchs...

Page 5: ... developed and manufactured in line with the applicable European standards and directives The product manufacturer Pepperl Fuchs Group 68307 Mannheim Germany has a certified quality assurance system that conforms to ISO 9001 Note A declaration of conformity can be requested from the manufacturer ISO9001 ...

Page 6: ...es may be performed only by trained and qualified personnel It is dangerous for the user to carry out modifications and or repairs and doing so will void the warranty and exclude the manufacturer from any liability In the event of any serious errors stop using the device Secure the device against unintended operation To have the device repaired return it to your local Pepperl Fuchs representative ...

Page 7: ...at are used to mark 3 important positions e g start stop and a third important position The actuator BT F130 A see chapter 4 3 is usually attached to the rotary system component to detect the position This actuator rotates in the central hole on the PMI360DV F130 3E2 V15 and contains the metal insert required for detecting the position The component is optimally adapted to the mechanical requireme...

Page 8: ...nt operating state of the device The LEDs S1 S2 and S3 are yellow and indicate the status of the device during the programming process and normal operation The programming buttons are used to program the angular positioning system The outer S1 S2 and S3 buttons are used to parameterize the start and end of the switching windows of the three independent switching stages on the sensor The S1 S2 and ...

Page 9: ...potential for electromagnetic interference please use shielded single ended female cordsets from our extensive range of accessories 4 3 2 Actuator The BT F130 A actuator is designed for mounting directly on the drive shaft or a servodrive Illustration Material Length Model number M12 x 1 straight 5 pin PVC 2 m 5 m 10 m V15 G 2M PVC V15 G 5M PVC V15 G 10M PVC PUR 2 m 5 m 10 m V15 G 2M PUR V15 G 5M ...

Page 10: ... is positioned in the center of the sensor so that the actuator does not rub against the sensor housing while the actuator is rotating Warning Risk of short circuit Working on live parts can cause injuries and can compromise the function and the electrical safety of the device Before working on the device always disconnect the supply voltage Connect the device to the supply voltage only after comp...

Page 11: ...distance to the sensitive surface on the sensor see table Failing to fulfill all of these requirements may reduce the accuracy resolution of the sensor or even prevent it from functioning Dimensions when using a different actuating element A Drive shaft B Insulation ring made from non conductive material C Different actuator L 23 mm D Sensitive surface on the sensor black cylindrical inner surface...

Page 12: ...eck that the wires are connected correctly before connecting the cordset to the sensor On Pepperl Fuchs cordsets the wire colors are assigned to the connecting pins in the connector according to DIN EN 60947 5 2 5 Attach the socket on the cordset to the connector on the sensor and tighten the union nut by hand 6 Switch on the operating voltage The Power Error LED on the sensor lights up green if t...

Page 13: ...nnecting pins in the connector according to DIN EN60947 5 2 Connector pin Function 1 UB 2 Switching output Q2 switching window S2 3 UB 4 Switching output Q1 switching window S1 5 Switching output Q3 switching window S3 Connecting pin Wire color 1 brown 2 white 3 blue 4 black 5 gray ...

Page 14: ...ng graphic illustrates the switching characteristics in principle using the example of the sensor at switching output S1 Figure 6 1 Program switching output 1 S1 as follows Programming switching output S1 1 Make sure that the sensor is mounted correctly and securely and check that an actuator with the specified dimensions is positioned at the correct distance from the surface of the sensor See cha...

Page 15: ...tor does not move between the time the switching window start and end points are programmed the smallest possible switching window is programmed with a width of 5 1 hysteresis The switching window midpoint is set at the programmed position The following graphic illustrates the switching characteristics in principle using the example of the sensor at switching output S1 2 5 2 5 H H S11 S12 3 5 3 5 ...

Page 16: ... the S2 button to do so The S2 LED indicates the status Note Activating the keylock The keylock is not activated initially Press any button on the sensor to determine whether the keylock is active If the color of the Power Error LED remains green the keylock is inactive and if the color of the Power Error LED changes to red the keylock is active To activate the keylock press and hold the S1 and S2...

Page 17: ...witching output S1 example 40 3 Position of the 2nd switch point of switching output S1 example 60 4 Position of the 1st switch point of switching output S2 example 250 5 Position of the 2nd switch point of switching output S2 example 310 6 Position of the 1st switch point of switching output S3 for example 110 7 Position of the 2nd switch point of switching output S3 for example 20 8 Output signa...

Page 18: ...mmed at any desired position If the actuator falls in one of the programmed switching windows the corresponding switching output is activated When a switching output is active the corresponding yellow LED lights up If the actuator is positioned outside of a programmed switching window the relevant switching output changes to an idle state When the actuator leaves the detection area of the angular ...

Page 19: ... functions can be reset to the factory set ting Factory setting PMI360DV F130 3E2 V15 Reset process 1 Press and hold the sensor button assigned to the output that you would like to reset The associated yellow LED starts to flash slowly after 2 seconds 2 Continue to hold the sensor button The LED begins to flash more quickly after an additional 10 seconds 3 Then release the button within 3 seconds ...

Page 20: ...s the associated LED starts to flash slowly again The Power Error LED then flashes red at the same time This fault signal indicates that a button is stuck A reset to the factory setting does not occur in this case As soon as the button is released the Power Error LED stops flashing red and lights up green permanently ...

Page 21: ...present or differ ent actuator mounted too far away from the surface of the sensor Mount actuator according to specifications Power Error LED lights up red during programming Actuator lost during the parameterization process or distance between actuator and surface of sensor too great different actuator Make sure that the concentric ity and adjustment of a differ ent actuator does not result in a ...

Page 22: ...faults with the wir ing Supply cable to the sensor is damaged Replace the damaged cable Power Error LED lights up red permanently or intermit tently No damping element in the sensing range of the sensor or unreliable detection of the damping element Check that the damping ele ment used is mounted cor rectly or install a damping element with appropriate dimensions at the correct dis tance from the ...

Page 23: ...osal Electronic waste is hazardous waste When disposing of the equipment observe the current statutory requirements in the respective country of use as well as local regulations The device does not contain any batteries that require separate disposal ...

Page 24: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 2025C ...

Reviews: