2
02
0-
01
10
Installation
5
Installation
5.1
Note on safety
5.2
Mounting
Mount the sensor as follows:
Mounting
1.
Place the sensor on a stable mounting bracket or another flat surface.
2.
Align the sensor so that the rotational axis of the movement that you wish to detect is positioned
centrally in relation to the housing bore.
3.
Secure the sensor using two M5 cylinder head screws (thread length
20 mm).
4.
Check that the sensor is seated firmly and securely.
5.
Unless already fitted, mount the actuator or a different actuator element on the rotational axis.
6.
Check that the actuator is positioned in the center of the sensor so that the actuator does not
rub against the sensor housing while the actuator is rotating.
Warning!
Risk of short circuit
Working on live parts can cause injuries and can compromise the function and the electrical
safety of the device.
•
Before working on the device, always disconnect the supply voltage.
•
Connect the device to the supply voltage only after completion of the work.
Caution!
Avoid suspended mounting at temperatures below 0
°
C and in humid environments!
In principle, the sensor can be installed in any position. However, avoid suspended mounting
(upside down) if the ambient temperature is below 0
°
C and in humid environments. Otherwise
moisture may penetrate the inside of the sensor during prolonged exposure.
10.3 ± 0.3
Ø5.2
Ø10
110
40
76.5
30
ø 41.5
26