40
POWERSCAN
Configuration PSCAN-D-1*
4.5.2
Custom Code Identifier
4.5.3
Header
Enter configuration
Exit and save configuration
Custom code identifier
Default: disabled
Define costom code identifiers
1.) Read the left code (EH).
2.) Select the code type from the code table
in for the identifier you want to change.
3.) You can define 1 or 2 identifier
characters for each code type. If only 1
identifier character is required, the second
character must be selected as FF
(disabled). Read the hexadecimal value
corresponding to the characters you want
to define as identifiers for the code selected
in step 2.) : valid characters are in the
range 00-FD.
Example: To define the Code 39 Code,
Identifier = @
+ Code 39 + 40
+FF
Enter configuration
Exit and save configuration
Header
no header (*)
one character header
two character header
three character header