POWERSCAN
Configuration PSCAN-D-1*
77
4.10
Advanced Formatting
The Default value is signed with (*)
To change the "Advanced Formatting" Default values
1. Read the "Enter Configuration" code once.
2. Read the configuration codes precisely following the numbered procedure given.
3. When desired you can change further configuration codes directly.
4. Read the "Exit and Save Configuration" code once.
4.10.1
Concatenation
Concatenation
Default Advanced Formatting
Parameter
Default
Concatenation
disabled
Advanced Formatting
no Advanced Formatting enabled
Enter configuration
Exit and save configuration
Concatenation disable (*)
Concatenation enable
Permits the concatenation of two codes
defined by code type and length. It is
possible to set a timeout for the second
code reading and to define code
transmission if the timeout expires. The
order of transmission is CODE 1 - CODE 2.
Define Concatenation Code 1
Code ID
Read the code type from the Code Identifier table.
Code length
Read an number in the range 0-99 from the Hex/Numeric table.