Installation
3.3
Electrical Connection
The reader is connected to an 8-pin M12 x 1 connector plug at the side of the housing with the
label
"Main"
. The power supply and communication with the SSI interface is established via
this connection. The configurable inputs and outputs on the reader are also located at this
connection.
Figure 3.4
Electrical Connection
Connections 1 and 8 can be configured as inputs or outputs.
Connector Assignment
Figure 3.5
Connector assignment
Color Assignment
Single-ended female cordsets by Fuchs are manufactured in accordance with
EN60947-5-2. When using a type V19-... single-ended female cordset with an open cable end
( ), the following color assignment applies:
Caution!
When selecting the length of the mounting screws, ensure that the maximum insertion depth of
the screws in the threaded inserts on the reader is 8 mm.
Using longer screws can damage the reader.
Caution!
The maximum torque of the mounting screws must not exceed 9 Nm.
Tightening the screws to a higher torque can damage the reader.