SLCT* and SLCT*/35 safety light curtains
Installation
4
Installation
4.1
Planning and Preparation
Safety distance
A minimum distance must be maintained between the protection field and the
danger zone to ensure potentially dangerous movements are brought to a stop
before contact with a person is possible.
Figure 4.1
Minimum distance between protection field and hazardous area
This distance is calculated from the lag time of the machine, the response time of
the safety system, and the speed of movement of the person entering the
hazardous area (ISO/EN 13855).
Warning!
Danger to life due to ineffective protective equipment
Improper or incorrect alignment, fixing, and connection to machine control can
impair the effectiveness of the protective function.
■
Note the applicable standards, guidelines, and legal regulations for the
equipment of machine and plants with protective equipment.
■
Position the protective equipment to prevent persons from being able to
reach or walk behind it, climb over or under, or otherwise bypass the
equipment in any way.
■
Use appropriate safety distances to take into account the response times
and lag times of the components in the safety chain.
■
Secure the protective equipment against manipulation or deliberate
deactivation.
Danger zone
Minimum interval S
Sending unit
Protective field
Receiving unit
SLCT* and SLCT*/35 safety light curtains