2
7
1
6
9
5
2
0
1
7
-1
2
28
SLCT* and SLCT*/35 safety light curtains
Commissioning
5
Commissioning
5.1
Functional Testing
Check the function of the transmitter and receiver
1.
Check whether the transmitter and receiver are aligned parallel to one another
and are at the same height.
2.
Switch on the safety light curtain when the protection field is clear.
3.
Adjust the transmitter and receiver so that the reception signal exceeds the
functional reserve.
If the reception signal falls below the functional reserve, the yellow
restart/status LED on the receiver flashes.
4.
Check whether the two OSSD outputs are switching on correctly. The
Ready
to start
message appears unless this operating mode is deactivated by an
external circuit.
5.
Use the supplied test rod to test the detection capability of the safety light
curtain to identify any detection gaps caused by reflective surfaces. (see
chapter 8.6.13).
6.
Check the effectiveness of the switch-off function of the safety light curtain
and the response time of the safety function when a beam is interrupted.
7.
If you are using the startup/restart interlock operating mode, test whether the
lock is enabled when the power is turned on and after the protection field is
interrupted.
8.
Check the function of the test input when the protection field is clear by
applying 24 V to the test input.
The OSSDs switch off and switch the OSSDs back on again after the test
has been completed successfully.
If the function "Relay monitor" is activated, the monitored switching elements
following the OSSDs accordingly.
Warning!
Danger to life due to unexpected machine startup if the startup/restart interlock is
incorrectly set up
If the startup/restart interlock does not function correctly when the power is
switched on and after the protection field is interrupted, this can lead to an
unexpected dangerous startup of the machine.
Before commissioning the machine, check whether the startup/restart interlock is
functioning correctly when the power is connected and following interruption of
the protection field.
SLCT* and SLCT*/35 safety light curtains